Optimal acquisition and modeling parameters for accurate assessment of low Ktrans blood–brain barrier permeability using dynamic contrast‐enhanced MRI. Issue 5 (16th June 2015)
- Record Type:
- Journal Article
- Title:
- Optimal acquisition and modeling parameters for accurate assessment of low Ktrans blood–brain barrier permeability using dynamic contrast‐enhanced MRI. Issue 5 (16th June 2015)
- Main Title:
- Optimal acquisition and modeling parameters for accurate assessment of low Ktrans blood–brain barrier permeability using dynamic contrast‐enhanced MRI
- Authors:
- Barnes, Samuel R.
Ng, Thomas S. C.
Montagne, Axel
Law, Meng
Zlokovic, Berislav V.
Jacobs, Russell E. - Abstract:
- Abstract : Purpose: To determine optimal parameters for acquisition and processing of dynamic contrast‐enhanced MRI (DCE‐MRI) to detect small changes in near normal low blood–brain barrier (BBB) permeability. Methods: Using a contrast‐to‐noise ratio metric (K‐CNR) for Ktrans precision and accuracy, the effects of kinetic model selection, scan duration, temporal resolution, signal drift, and length of baseline on the estimation of low permeability values was evaluated with simulations. Results: The Patlak model was shown to give the highest K‐CNR at low Ktrans . The Ktrans transition point, above which other models yielded superior results, was highly dependent on scan duration and tissue extravascular extracellular volume fraction (ve ). The highest K‐CNR for low Ktrans was obtained when Patlak model analysis was combined with long scan times (10–30 min), modest temporal resolution (<60 s/image), and long baseline scans (1–4 min). Signal drift as low as 3% was shown to affect the accuracy of Ktrans estimation with Patlak analysis. Conclusion: DCE acquisition and modeling parameters are interdependent and should be optimized together for the tissue being imaged. Appropriately optimized protocols can detect even the subtlest changes in BBB integrity and may be used to probe the earliest changes in neurodegenerative diseases such as Alzheimer's disease and multiple sclerosis. Magn Reson Med 75:1967–1977, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 5(2016)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 5(2016)
- Issue Display:
- Volume 75, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 5
- Issue Sort Value:
- 2016-0075-0005-0000
- Page Start:
- 1967
- Page End:
- 1977
- Publication Date:
- 2015-06-16
- Subjects:
- Ktrans estimation -- DCE‐MRI -- blood–brain barrier -- parameter optimization -- permeability
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25793 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2405.xml