Aortic Root Distortion and Aortic Insufficiency During Balloon Angioplasty of the Right Ventricular Outflow Tract Prior to Transcatheter Pulmonary Valve Replacement. (29th January 2016)
- Record Type:
- Journal Article
- Title:
- Aortic Root Distortion and Aortic Insufficiency During Balloon Angioplasty of the Right Ventricular Outflow Tract Prior to Transcatheter Pulmonary Valve Replacement. (29th January 2016)
- Main Title:
- Aortic Root Distortion and Aortic Insufficiency During Balloon Angioplasty of the Right Ventricular Outflow Tract Prior to Transcatheter Pulmonary Valve Replacement
- Authors:
- Torres, Alejandro J.
McElhinney, Doff B.
Anderson, Brett R.
Turner, Mariel E.
Crystal, Matthew A.
Timchak, Donna M.
Vincent, Julie A. - Abstract:
- Abstract : Objective: To describe the significance of aortic root distortion (AD) and/or aortic valve insufficiency (AI) during balloon angioplasty of the right ventricular outflow tract (RVOT) performed to rule out coronary artery compression prior to transcatheter pulmonary valve (TPV) implantation. Methods: AD/AI was assessed by retrospective review of all procedural aortographies performed to evaluate coronary anatomy prior to TPV implantation. AD/AI was also reviewed in all pre‐post MPV implant echocardiograms to assess for progression. Results: From 04/2007 to 3/2015, 118 pts underwent catheterization with intent for TPV implant. Mean age and weight were 24.5 ± 12 years and 64.3 ± 20 kg, respectively. Diagnoses were: TOF (53%), D‐TGA/DORV (18%), s/p Ross (15%), and Truncus (9%). Types of RV‐PA connections were: conduits (96), bioprosthetic valves (14), and other (7). Successful TPV implant occurred in 91 pts (77%). RVOT balloon angioplasty was performed in 43/118 pts (36%). Aortography was performed in 18/43 pts with AD/AI noted in 6/18 (33%); 2 with D‐TGA (1 s/p Lecompte, 1 s/p Rastelli), 2 with TOF, 1 Truncus and 1 s/p Ross. Procedure was aborted in the 2 who developed severe AD/AI. TPV was implanted in 3/4 patients with mild AD/AI. Review of pre‐post TPV implantation echocardiograms in 83/91 pts (91%) revealed no new/worsened AI in any patient. Conclusion: AD/AI is relatively common on aortography during simultaneous RVOT balloon angioplasty. Lack of AI progressionAbstract : Objective: To describe the significance of aortic root distortion (AD) and/or aortic valve insufficiency (AI) during balloon angioplasty of the right ventricular outflow tract (RVOT) performed to rule out coronary artery compression prior to transcatheter pulmonary valve (TPV) implantation. Methods: AD/AI was assessed by retrospective review of all procedural aortographies performed to evaluate coronary anatomy prior to TPV implantation. AD/AI was also reviewed in all pre‐post MPV implant echocardiograms to assess for progression. Results: From 04/2007 to 3/2015, 118 pts underwent catheterization with intent for TPV implant. Mean age and weight were 24.5 ± 12 years and 64.3 ± 20 kg, respectively. Diagnoses were: TOF (53%), D‐TGA/DORV (18%), s/p Ross (15%), and Truncus (9%). Types of RV‐PA connections were: conduits (96), bioprosthetic valves (14), and other (7). Successful TPV implant occurred in 91 pts (77%). RVOT balloon angioplasty was performed in 43/118 pts (36%). Aortography was performed in 18/43 pts with AD/AI noted in 6/18 (33%); 2 with D‐TGA (1 s/p Lecompte, 1 s/p Rastelli), 2 with TOF, 1 Truncus and 1 s/p Ross. Procedure was aborted in the 2 who developed severe AD/AI. TPV was implanted in 3/4 patients with mild AD/AI. Review of pre‐post TPV implantation echocardiograms in 83/91 pts (91%) revealed no new/worsened AI in any patient. Conclusion: AD/AI is relatively common on aortography during simultaneous RVOT balloon angioplasty. Lack of AI progression by echocardiography post‐TPV implant suggests these may be benign findings in most cases. However, AD/AI should be carefully evaluated in certain anatomic subtypes with close RVOT/aortic alignments. (J Interven Cardiol 2016;29:197–207) … (more)
- Is Part Of:
- Journal of interventional cardiology. Volume 29:Number 2(2016:Apr.)
- Journal:
- Journal of interventional cardiology
- Issue:
- Volume 29:Number 2(2016:Apr.)
- Issue Display:
- Volume 29, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2016-0029-0002-0000
- Page Start:
- 197
- Page End:
- 207
- Publication Date:
- 2016-01-29
- Subjects:
- Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.1206 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8183 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=joic ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/joic.12270 ↗
- Languages:
- English
- ISSNs:
- 0896-4327
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5007.696000
British Library STI - ELD Digital store - Ingest File:
- 199.xml