Interpretation of intraoperative recurrent laryngeal nerve monitoring signals: The importance of a correct standardization. (April 2016)
- Record Type:
- Journal Article
- Title:
- Interpretation of intraoperative recurrent laryngeal nerve monitoring signals: The importance of a correct standardization. (April 2016)
- Main Title:
- Interpretation of intraoperative recurrent laryngeal nerve monitoring signals: The importance of a correct standardization
- Authors:
- Calò, Pietro Giorgio
Medas, Fabio
Gordini, Luca
Podda, Francesco
Erdas, Enrico
Pisano, Giuseppe
Nicolosi, Angelo - Abstract:
- Abstract: Introduction: Despite the increasingly broad use of intraoperative neuromonitoring, review of the literature and clinical experience confirms there is little uniformity in application of and results across different centers. The aim of this study was to evaluate the ability of intraoperative neuromonitoring with a standardized evaluation of the signals to predict the postoperative functional outcome and its role in reducing the postoperative recurrent nerve palsy rates. Methods: 2365 consecutive patients underwent thyroidectomy by a single surgical team: in 1356 patients (group A) with intraoperative neuromonitoring, in 1009 (Group B) without it. Results: In group A a loss of signal was observed in 37 cases: we had 29 true positive cases, 1317 true negative, 8 false positive, and 2 false negative. Accuracy was 99.26%, positive predictive value 78.38%, negative predictive value 99.85%, sensitivity 93.55%, and specificity 99.4%. 29 unilateral nerve paralysis were observed (2.13%), 23 (1.69%) transient and 6 (0.44%) permanent. In group B 26 unilateral paralysis were observed (2.57%), 20 (1.98%) transient and 6 permanent (0.59%) Differences were not statistically significant. Conclusions: Intraoperative neuromonitoring is highly predictive of the postoperative nerve function. We obtained a very high sensitivity and negative predictive value, but also a good specificity and positive predictive value. For these reasons, in selected patients with loss of signal, theAbstract: Introduction: Despite the increasingly broad use of intraoperative neuromonitoring, review of the literature and clinical experience confirms there is little uniformity in application of and results across different centers. The aim of this study was to evaluate the ability of intraoperative neuromonitoring with a standardized evaluation of the signals to predict the postoperative functional outcome and its role in reducing the postoperative recurrent nerve palsy rates. Methods: 2365 consecutive patients underwent thyroidectomy by a single surgical team: in 1356 patients (group A) with intraoperative neuromonitoring, in 1009 (Group B) without it. Results: In group A a loss of signal was observed in 37 cases: we had 29 true positive cases, 1317 true negative, 8 false positive, and 2 false negative. Accuracy was 99.26%, positive predictive value 78.38%, negative predictive value 99.85%, sensitivity 93.55%, and specificity 99.4%. 29 unilateral nerve paralysis were observed (2.13%), 23 (1.69%) transient and 6 (0.44%) permanent. In group B 26 unilateral paralysis were observed (2.57%), 20 (1.98%) transient and 6 permanent (0.59%) Differences were not statistically significant. Conclusions: Intraoperative neuromonitoring is highly predictive of the postoperative nerve function. We obtained a very high sensitivity and negative predictive value, but also a good specificity and positive predictive value. For these reasons, in selected patients with loss of signal, the surgical strategy can be reconsidered. On the other hand, this study failed to demonstrate a statistically significant decrease in the nerve paralysis rate. Further studies are needed to better evaluate the real benefit of this technique. Highlights: Intraoperative neuromonitoring is highly predictive of the postoperative nerve function. Standardization permits high sensibility and negative predictive value, but also specificity and positive predictive value. In selected patients with loss of signal the surgical strategy can be reconsidered. This study failed to demonstrate a statistically significant decrease in the nerve paralysis rate. Further studies are needed to better evaluate the real benefit of this technique. … (more)
- Is Part Of:
- International journal of surgery. Volume 28(2016)Supplement 1
- Journal:
- International journal of surgery
- Issue:
- Volume 28(2016)Supplement 1
- Issue Display:
- Volume 28, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 28
- Issue:
- 1
- Issue Sort Value:
- 2016-0028-0001-0000
- Page Start:
- S54
- Page End:
- S58
- Publication Date:
- 2016-04
- Subjects:
- Recurrent laryngeal nerve -- Intraoperative neuromonitoring -- Thyroid surgery -- Nerve injury
Surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
617.005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17439191 ↗
http://ees.elsevier.com/ijs/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijsu.2015.12.039 ↗
- Languages:
- English
- ISSNs:
- 1743-9191
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.685050
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1671.xml