Multi–spin echo spatial encoding provides three‐fold improvement of temperature precision during intermolecular zero quantum thermometry. Issue 5 (16th June 2015)
- Record Type:
- Journal Article
- Title:
- Multi–spin echo spatial encoding provides three‐fold improvement of temperature precision during intermolecular zero quantum thermometry. Issue 5 (16th June 2015)
- Main Title:
- Multi–spin echo spatial encoding provides three‐fold improvement of temperature precision during intermolecular zero quantum thermometry
- Authors:
- Davis, Ryan M.
Zhou, Zijian
Chung, Hyunkoo
Warren, Warren S. - Abstract:
- Abstract : Purpose: Intermolecular multiple quantum coherences (iMQCs) are a source of MR contrast with applications including temperature imaging, anisotropy mapping, and brown fat imaging. Because all applications are limited by signal‐to‐noise ratio (SNR), we developed a pulse sequence that detects intermolecular zero quantum coherences with improved SNR. Methods: A previously developed pulse sequence that detects iMQCs, HOMOGENIZED with off resonance transfer (HOT), was modified with a multi‐spin echo spatial encoding scheme (MSE‐HOT). MSE‐HOT uses a series of refocusing pulses to generate a stack of images that are averaged in postprocessing for higher SNR. MSE‐HOT performance was quantified by measuring its temperature accuracy and precision during hyperthermia of ex vivo red bone marrow samples. Results: MSE‐HOT yielded a three‐fold improvement in temperature precision relative to previous pulse sequences. Sources of improved precision were 1) echo averaging and 2) suppression of J‐coupling in the methylene protons of fat. MSE‐HOT measured temperature change with an accuracy of 0.6°C. Conclusion: MSE‐HOT improved the temperature accuracy and precision of HOT to a level that is sufficient for hyperthermia of bone marrow. Magn Reson Med 75:1958–1966, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 5(2016)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 5(2016)
- Issue Display:
- Volume 75, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 5
- Issue Sort Value:
- 2016-0075-0005-0000
- Page Start:
- 1958
- Page End:
- 1966
- Publication Date:
- 2015-06-16
- Subjects:
- intermolecular multiple quantum coherence -- temperature imaging -- red bone marrow -- Carr‐Purcell‐Meiboom‐Gill
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25789 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2405.xml