Dynamic contrast‐enhanced ultrasound parametric imaging for the detection of prostate cancer. (29th June 2015)
- Record Type:
- Journal Article
- Title:
- Dynamic contrast‐enhanced ultrasound parametric imaging for the detection of prostate cancer. (29th June 2015)
- Main Title:
- Dynamic contrast‐enhanced ultrasound parametric imaging for the detection of prostate cancer
- Authors:
- Postema, Arnoud W.
Frinking, Peter J.A.
Smeenge, Martijn
De Reijke, Theo M.
De la Rosette, Jean J.M.C.H.
Tranquart, Francois
Wijkstra, Hessel - Abstract:
- Abstract : Objective: To investigate the value of dynamic contrast‐enhanced (DCE)‐ultrasonography (US) and software‐generated parametric maps in predicting biopsy outcome and their potential to reduce the amount of negative biopsy cores. Materials and Methods: For 651 prostate biopsy locations (82 consecutive patients) we correlated the interpretation of DCE‐US recordings with and without parametric maps with biopsy results. The parametric maps were generated by software which extracts perfusion parameters that differentiate benign from malignant tissue from DCE‐US recordings. We performed a stringent analysis (all tumours) and a clinical analysis (clinically significant tumours). We calculated the potential reduction in biopsies (benign on imaging) and the resultant missed positive biopsies (false‐negatives). Additionally, we evaluated the performance in terms of sensitivity, specificity negative predictive value (NPV) and positive predictive value (PPV) on a per‐prostate level. Results: Based on DCE‐US, 470/651 (72.2%) of biopsy locations appeared benign, resulting in 40 false‐negatives (8.5%), considering clinically significant tumours only. Including parametric maps, 411/651 (63.1%) of the biopsy locations appeared benign, resulting in 23 false‐negatives (5.6%). In the per‐prostate clinical analysis, DCE‐US classified 38/82 prostates as benign, missing eight diagnoses. Including parametric maps, 31/82 prostates appeared benign, missing three diagnoses. Sensitivity,Abstract : Objective: To investigate the value of dynamic contrast‐enhanced (DCE)‐ultrasonography (US) and software‐generated parametric maps in predicting biopsy outcome and their potential to reduce the amount of negative biopsy cores. Materials and Methods: For 651 prostate biopsy locations (82 consecutive patients) we correlated the interpretation of DCE‐US recordings with and without parametric maps with biopsy results. The parametric maps were generated by software which extracts perfusion parameters that differentiate benign from malignant tissue from DCE‐US recordings. We performed a stringent analysis (all tumours) and a clinical analysis (clinically significant tumours). We calculated the potential reduction in biopsies (benign on imaging) and the resultant missed positive biopsies (false‐negatives). Additionally, we evaluated the performance in terms of sensitivity, specificity negative predictive value (NPV) and positive predictive value (PPV) on a per‐prostate level. Results: Based on DCE‐US, 470/651 (72.2%) of biopsy locations appeared benign, resulting in 40 false‐negatives (8.5%), considering clinically significant tumours only. Including parametric maps, 411/651 (63.1%) of the biopsy locations appeared benign, resulting in 23 false‐negatives (5.6%). In the per‐prostate clinical analysis, DCE‐US classified 38/82 prostates as benign, missing eight diagnoses. Including parametric maps, 31/82 prostates appeared benign, missing three diagnoses. Sensitivity, specificity, PPV and NPV were 73, 58, 50 and 79%, respectively, for DCE‐US alone and 91, 56, 57 and 90%, respectively, with parametric maps. Conclusion: The interpretation of DCE‐US with parametric maps allows good prediction of biopsy outcome. A two‐thirds reduction in biopsy cores seems feasible with only a modest decrease in cancer diagnosis. … (more)
- Is Part Of:
- BJU international. Volume 117:Number 4(2016:Feb.)
- Journal:
- BJU international
- Issue:
- Volume 117:Number 4(2016:Feb.)
- Issue Display:
- Volume 117, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 117
- Issue:
- 4
- Issue Sort Value:
- 2016-0117-0004-0000
- Page Start:
- 598
- Page End:
- 603
- Publication Date:
- 2015-06-29
- Subjects:
- prostate cancer imaging -- contrast‐enhanced ultrasound -- parametric imaging -- quantification
Genitourinary organs -- Diseases -- Periodicals
Genitourinary organs -- Surgery -- Periodicals
Urology -- Periodicals
616.6 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1464-410X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/bju.13116 ↗
- Languages:
- English
- ISSNs:
- 1464-4096
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2105.758000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2045.xml