DNA degradation in liquid‐based cytology and its comparison with conventional smear. Issue 5 (23rd January 2016)
- Record Type:
- Journal Article
- Title:
- DNA degradation in liquid‐based cytology and its comparison with conventional smear. Issue 5 (23rd January 2016)
- Main Title:
- DNA degradation in liquid‐based cytology and its comparison with conventional smear
- Authors:
- Kim, Wook Youn
Oh, Seo Young
Kim, Hyunkyung
Hwang, Tae Sook - Abstract:
- Abstract : Background: In fine needle aspiration biopsy (FNAB) of thyroid nodules, LBC is adopted in most of the hospitals and clinics in Korea for its convenience. BRAF mutation test has been introduced as an important ancillary test, but its applicability has not been completely proven with LBC samples. Methods: Five aspirates from thyroidectomy specimens were simultaneously processed into LBC and CS slides, in which BRAF mutation tests were performed using three primer sets with PCR products of 72, 164, and 226 base pairs (bp) at 6, 9, and 12 months after processing. In addition, BRAF mutation tests were performed in nine clinical samples that had been prepared by LBC or CS and stored for 3–5 years after processing. Results: At 9 months after processing, LBC failed to provide DNA of sufficient quality for PCR, whereas CS succeeded with primers for amplifying a 226 bp fragment. Furthermore, CS had successful amplification of DNA despite a delay of more than 1 year. The failure of DNA amplification in LBC was overcome by using primers to amplify shorter PCR products, suggesting that DNA degradation occurred in LBC. However, false positive or negative results were observed in primers for amplifying shorter size. The kind of preservative solutions used in LBC did not affect test results. Conclusion: LBC may have disadvantages in long‐term DNA preservation because of its accelerated DNA degradation compared with alcohol‐fixed CS. Using primers to amplify shorter size fragmentsAbstract : Background: In fine needle aspiration biopsy (FNAB) of thyroid nodules, LBC is adopted in most of the hospitals and clinics in Korea for its convenience. BRAF mutation test has been introduced as an important ancillary test, but its applicability has not been completely proven with LBC samples. Methods: Five aspirates from thyroidectomy specimens were simultaneously processed into LBC and CS slides, in which BRAF mutation tests were performed using three primer sets with PCR products of 72, 164, and 226 base pairs (bp) at 6, 9, and 12 months after processing. In addition, BRAF mutation tests were performed in nine clinical samples that had been prepared by LBC or CS and stored for 3–5 years after processing. Results: At 9 months after processing, LBC failed to provide DNA of sufficient quality for PCR, whereas CS succeeded with primers for amplifying a 226 bp fragment. Furthermore, CS had successful amplification of DNA despite a delay of more than 1 year. The failure of DNA amplification in LBC was overcome by using primers to amplify shorter PCR products, suggesting that DNA degradation occurred in LBC. However, false positive or negative results were observed in primers for amplifying shorter size. The kind of preservative solutions used in LBC did not affect test results. Conclusion: LBC may have disadvantages in long‐term DNA preservation because of its accelerated DNA degradation compared with alcohol‐fixed CS. Using primers to amplify shorter size fragments might be helpful in mitigating loss of signal due to DNA degradation in LBC. Diagn. Cytopathol. 2016;44:450–458. © 2016 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Diagnostic cytopathology. Volume 44:Issue 5(2016)
- Journal:
- Diagnostic cytopathology
- Issue:
- Volume 44:Issue 5(2016)
- Issue Display:
- Volume 44, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 5
- Issue Sort Value:
- 2016-0044-0005-0000
- Page Start:
- 450
- Page End:
- 458
- Publication Date:
- 2016-01-23
- Subjects:
- thyroid -- fine needle aspiration -- liquid‐based cytology -- conventional smear -- DNA degradation -- BRAF mutation test
Cytodiagnosis -- Periodicals
Pathology, Cellular -- Periodicals
Cytology -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0339 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dc.23441 ↗
- Languages:
- English
- ISSNs:
- 8755-1039
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3579.656500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 829.xml