Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) – A human cadaver pilot study. (May 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) – A human cadaver pilot study. (May 2016)
- Main Title:
- Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) – A human cadaver pilot study
- Authors:
- Piegeler, Tobias
Roessler, Bernard
Goliasch, Georg
Fischer, Henrik
Schlaepfer, Martin
Lang, Susanna
Ruetzler, Kurt - Abstract:
- Abstract: Background: Chest compressions and ventilation are lifesaving tasks during cardio-pulmonary resuscitation (CPR). Besides oxygenation, endotracheal intubation (ETI) during CPR is performed to avoid aspiration of gastric contents. If intubation is difficult or impossible, supraglottic airway devices are utilized. We tested six different airway devices regarding their potential to protect against regurgitation and aspiration during CPR in a randomized experimental human cadaver study. Methods: Five-hundred ml of 0.01% methylene-blue-solution were instilled into the stomach of 30 adult human cadavers via an oro-gastric tube. The cadavers were then randomly assigned to one of six groups, resulting in 5 cadavers in each group. Airway management was performed with either bag-valve ventilation, Laryngeal Tube, EasyTube, Laryngeal Mask (Classic), I-Gel, or ETI. Thereafter 5 min of CPR were performed according to the 2010 Guidelines of the European Resuscitation Council. Pulmonary aspiration was defined as the presence of methylene-blue-solution below the vocal cords or the ETI cuff as assessed by fiber-optic bronchoscopy. Results: Thirty cadavers were included (14 females, 16 males). Aspiration was detected in three out of five cadavers receiving bag-valve ventilation and in two out of five intubated with LMA or I-Gel. In cadavers intubated with the LT, aspiration occurred in one out of five cases. No aspiration could be detected in cadavers intubated with ETI and EasyTube.Abstract: Background: Chest compressions and ventilation are lifesaving tasks during cardio-pulmonary resuscitation (CPR). Besides oxygenation, endotracheal intubation (ETI) during CPR is performed to avoid aspiration of gastric contents. If intubation is difficult or impossible, supraglottic airway devices are utilized. We tested six different airway devices regarding their potential to protect against regurgitation and aspiration during CPR in a randomized experimental human cadaver study. Methods: Five-hundred ml of 0.01% methylene-blue-solution were instilled into the stomach of 30 adult human cadavers via an oro-gastric tube. The cadavers were then randomly assigned to one of six groups, resulting in 5 cadavers in each group. Airway management was performed with either bag-valve ventilation, Laryngeal Tube, EasyTube, Laryngeal Mask (Classic), I-Gel, or ETI. Thereafter 5 min of CPR were performed according to the 2010 Guidelines of the European Resuscitation Council. Pulmonary aspiration was defined as the presence of methylene-blue-solution below the vocal cords or the ETI cuff as assessed by fiber-optic bronchoscopy. Results: Thirty cadavers were included (14 females, 16 males). Aspiration was detected in three out of five cadavers receiving bag-valve ventilation and in two out of five intubated with LMA or I-Gel. In cadavers intubated with the LT, aspiration occurred in one out of five cases. No aspiration could be detected in cadavers intubated with ETI and EasyTube. Conclusion: This study provides experimental evidence that, during CPR, ETI offers superior protection against regurgitation and pulmonary aspiration of gastric contents than supraglottic airway devices or bag-valve ventilation. … (more)
- Is Part Of:
- Resuscitation. Volume 102(2016)
- Journal:
- Resuscitation
- Issue:
- Volume 102(2016)
- Issue Display:
- Volume 102, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 102
- Issue:
- 2016
- Issue Sort Value:
- 2016-0102-2016-0000
- Page Start:
- 70
- Page End:
- 74
- Publication Date:
- 2016-05
- Subjects:
- Airway management -- Pulmonary aspiration -- Cardio Pulmonary Resuscitation (CPR)
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2016.02.017 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1159.xml