Multiple partial discharge source discrimination with multiclass support vector machines. (15th August 2016)
- Record Type:
- Journal Article
- Title:
- Multiple partial discharge source discrimination with multiclass support vector machines. (15th August 2016)
- Main Title:
- Multiple partial discharge source discrimination with multiclass support vector machines
- Authors:
- Robles, Guillermo
Parrado-Hernández, Emilio
Ardila-Rey, Jorge
Martínez-Tarifa, Juan Manuel - Abstract:
- Highlights: Different types of partial discharges are created with test objects in laboratory. Their frequency content depends on the type of discharge and other external factors. An SVM extracts characteristics from the power spectral density of the pulses. Noise, corona, internal and surface discharges have different characteristics. The differences are used to classify discharges and separate them from noise. Abstract: The costs of decommissioning high-voltage equipment due to insulation breakdown are associated to the substitution of the asset and to the interruption of service. They can reach millions of dollars in new equipment purchases, fines and civil lawsuits, aggravated by the negative perception of the grid utility. Thus, condition based maintenance techniques are widely applied to have information about the status of the machine or power cable readily available. Partial discharge (PD) measurements are an important tool in the diagnosis of power systems equipment. The presence of PD can accelerate the local degradation of insulation systems and generate premature failures. Conventionally, PD classification is carried out using the phase resolved partial discharge (PRPD) pattern of pulses. The PRPD is a two dimensional representation of pulses that enables visual inspection but lacks discriminative power in common scenarios found in industrial environments, such as many simultaneous PD sources and low magnitude events that can be hidden below noise. The literatureHighlights: Different types of partial discharges are created with test objects in laboratory. Their frequency content depends on the type of discharge and other external factors. An SVM extracts characteristics from the power spectral density of the pulses. Noise, corona, internal and surface discharges have different characteristics. The differences are used to classify discharges and separate them from noise. Abstract: The costs of decommissioning high-voltage equipment due to insulation breakdown are associated to the substitution of the asset and to the interruption of service. They can reach millions of dollars in new equipment purchases, fines and civil lawsuits, aggravated by the negative perception of the grid utility. Thus, condition based maintenance techniques are widely applied to have information about the status of the machine or power cable readily available. Partial discharge (PD) measurements are an important tool in the diagnosis of power systems equipment. The presence of PD can accelerate the local degradation of insulation systems and generate premature failures. Conventionally, PD classification is carried out using the phase resolved partial discharge (PRPD) pattern of pulses. The PRPD is a two dimensional representation of pulses that enables visual inspection but lacks discriminative power in common scenarios found in industrial environments, such as many simultaneous PD sources and low magnitude events that can be hidden below noise. The literature shows several works that complement PRPD with machine learning detectors (neural networks and support vector machines) and with more sophisticated signal representations, like statistics captured in several modalities, wavelets and other transforms, etc. These methods improve the classification accuracy but obscure the interpretation of the results. In this paper, the use of a support vector machine (SVM) operating on the power spectrum density of signals is proposed to identify different pulses what could be used in an online tool in the maintenance decision-making of the utility. Particularly, the approach is based on an SVM endowed with a special kernel that operates in the frequency domain. The SVM is previously trained with pulses of different PD types (internal, surface and corona) and noise that are obtained with several test objects in the laboratory. The experimental results demonstrate that this technique is highly effective in identifying PD for cases where several sources are active or when the noise level is high. Thus, the early identification of critical events with this approach during normal operation of the equipment will help in the decision of decommissioning the asset with reduced costs and low impact to the grid reliability. … (more)
- Is Part Of:
- Expert systems with applications. Volume 55(2016)
- Journal:
- Expert systems with applications
- Issue:
- Volume 55(2016)
- Issue Display:
- Volume 55, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 55
- Issue:
- 2016
- Issue Sort Value:
- 2016-0055-2016-0000
- Page Start:
- 417
- Page End:
- 428
- Publication Date:
- 2016-08-15
- Subjects:
- Support vector machine -- Partial discharges -- Electric maintenance -- Machine learning -- Condition monitoring -- Risk assessment
Expert systems (Computer science) -- Periodicals
Systèmes experts (Informatique) -- Périodiques
Electronic journals
006.33 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09574174 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.eswa.2016.02.014 ↗
- Languages:
- English
- ISSNs:
- 0957-4174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.004220
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 499.xml