Comparison of predictive accuracy of teicoplanin concentration using creatinine clearance and glomerular filtration rate estimated by serum creatinine or cystatin C. Issue 5 (May 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of predictive accuracy of teicoplanin concentration using creatinine clearance and glomerular filtration rate estimated by serum creatinine or cystatin C. Issue 5 (May 2016)
- Main Title:
- Comparison of predictive accuracy of teicoplanin concentration using creatinine clearance and glomerular filtration rate estimated by serum creatinine or cystatin C
- Authors:
- Kozono, Aki
Hiraki, Yoichi
Adachi, Rui
Nagano, Masahisa
Inoue, Daisuke
Tsuji, Yasuhiro
Kamimura, Hidetoshi
Karube, Yoshiharu - Abstract:
- Abstract: We compared the predictive accuracy of TEIC concentrations (TEIC _conc ) calculated using either serum cystatin C (CysC) or serum creatinine (SCr) and the population mean method using the mean population parameter of TEIC _conc for Japan. We also compared the predicted TEIC _conc to measured TEIC _conc . Creatinine clearance (CLCr) predicted using the Cockcroft–Gault (C&G) equation with SCr was 45.23 mL/min (interquartile range [IQR]: 32.12–58.28), and the glomerular filtration rate (GFR) predicted using the Hoek equation with CysC was 45.23 mL/min (IQR: 35.40–53.79). The root mean-squared prediction error (IQR) based on CLCr predicted using the C&G equation with SCr was 6.88 (3.80–9.96) μg/mL, and that based on GFR predicted using the Hoek equation with CysC was 6.72 (3.77–9.68) μg/mL. Predicted TEIC _conc did not differ significantly between the two methods. The predictive accuracy of the TEIC _conc using the Hoek equation with CysC was similar to that of CLCr using the C&G equation with SCr. These findings suggest that the predictive accuracy of the TEIC _conc using CLCr based on the G&G equation and SCr might be sufficient for the initial dose adjustment of TEIC. Given that we were unable to confirm that CysC is the optimal method for predicting TEIC _conc, the expensive measurement of CysC might not be necessary.
- Is Part Of:
- Journal of infection and chemotherapy. Volume 22:Issue 5(2016:May)
- Journal:
- Journal of infection and chemotherapy
- Issue:
- Volume 22:Issue 5(2016:May)
- Issue Display:
- Volume 22, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 22
- Issue:
- 5
- Issue Sort Value:
- 2016-0022-0005-0000
- Page Start:
- 314
- Page End:
- 318
- Publication Date:
- 2016-05
- Subjects:
- Cockcroft–Gault equation -- Cystatin C -- Hoek equation -- Predictive accuracy -- Serum creatinine -- Teicoplanin
Chemotherapy -- Periodicals
Infection -- Periodicals
Communicable diseases -- Chemotherapy -- Periodicals
615.5805 - Journal URLs:
- http://www.sciencedirect.com/science/journal/1341321X ↗
http://link.springer-ny.com/link/service/journals/10156/index.htm ↗
http://www.springerlink.com/content/1341-321x ↗
http://www.elsevier.com/journals ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1016/j.jiac.2016.01.024 ↗
- Languages:
- English
- ISSNs:
- 1341-321X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5006.691000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 348.xml