Comparative study on the cooling characteristics of high level water collecting natural draft wet cooling tower and the usual cooling tower. (15th May 2016)
- Record Type:
- Journal Article
- Title:
- Comparative study on the cooling characteristics of high level water collecting natural draft wet cooling tower and the usual cooling tower. (15th May 2016)
- Main Title:
- Comparative study on the cooling characteristics of high level water collecting natural draft wet cooling tower and the usual cooling tower
- Authors:
- Zhao, Yuanbin
Sun, Fengzhong
Long, Guoqing
Huang, Xiaofeng
Huang, Wenqiang
Lyv, Dongqiang - Abstract:
- Highlights: The 3D numerical models for HNDWCT and UNDWCTs were established and validated. Comparing with UNDWCTs, the cooling characteristics of HNDWCT were highlighted. The high air–water mass flow rate ratio of HNDWCT amplifies its fill cooling load. The minimum heat and mass transfer intensity in HNDWCT occurs near the tower wall. Blocking the cross ventilation is favorable to HNDWCT at high velocity crosswinds. Abstract: With the rapid development of large capacity power units, high level water collecting natural draft wet cooling towers (HNDWCTs) are now attractive. To study the cooling characteristics of HNDWCT, a three-dimensional (3D) numerical model for a HNDWCT was established and validated. Combining with the verified 3D numerical models for usual natural draft wet cooling towers (UNDWCTs), the parameters such as air pressure drop, air mass flow rate, exit water temperature, cooling load percentage of each zone, air velocity, air temperature and H2 O mass fraction were elaborated for HNDWCT and UNDWCTs under the same work conditions. Comparing with UNDWCTs, the cooling characteristics of HNDWCT were analyzed and highlighted. The cooling load percentage of fill zone in HNDWCT is far larger than those in UNDWCTs for the large air mass flow rate and large heat transfer potential. Under high velocity crosswind impacts, blocking the cross ventilation through HNDWCT is favorable to its cooling performance. Suggestions concerning the orientations of water collectingHighlights: The 3D numerical models for HNDWCT and UNDWCTs were established and validated. Comparing with UNDWCTs, the cooling characteristics of HNDWCT were highlighted. The high air–water mass flow rate ratio of HNDWCT amplifies its fill cooling load. The minimum heat and mass transfer intensity in HNDWCT occurs near the tower wall. Blocking the cross ventilation is favorable to HNDWCT at high velocity crosswinds. Abstract: With the rapid development of large capacity power units, high level water collecting natural draft wet cooling towers (HNDWCTs) are now attractive. To study the cooling characteristics of HNDWCT, a three-dimensional (3D) numerical model for a HNDWCT was established and validated. Combining with the verified 3D numerical models for usual natural draft wet cooling towers (UNDWCTs), the parameters such as air pressure drop, air mass flow rate, exit water temperature, cooling load percentage of each zone, air velocity, air temperature and H2 O mass fraction were elaborated for HNDWCT and UNDWCTs under the same work conditions. Comparing with UNDWCTs, the cooling characteristics of HNDWCT were analyzed and highlighted. The cooling load percentage of fill zone in HNDWCT is far larger than those in UNDWCTs for the large air mass flow rate and large heat transfer potential. Under high velocity crosswind impacts, blocking the cross ventilation through HNDWCT is favorable to its cooling performance. Suggestions concerning the orientations of water collecting gutter and cross wall are presented. … (more)
- Is Part Of:
- Energy conversion and management. Volume 116(2016)
- Journal:
- Energy conversion and management
- Issue:
- Volume 116(2016)
- Issue Display:
- Volume 116, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 116
- Issue:
- 2016
- Issue Sort Value:
- 2016-0116-2016-0000
- Page Start:
- 150
- Page End:
- 164
- Publication Date:
- 2016-05-15
- Subjects:
- Natural draft wet cooling tower -- High level water collecting devices -- Numerical simulation -- Cooling performance -- Crosswind
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2016.02.071 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 758.xml