Accuracy evaluation of computer-designed surgical guide template in oral implantology. Issue 10 (December 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy evaluation of computer-designed surgical guide template in oral implantology. Issue 10 (December 2015)
- Main Title:
- Accuracy evaluation of computer-designed surgical guide template in oral implantology
- Authors:
- Shen, Pei
Zhao, Jingyang
Fan, Linfeng
Qiu, Hanxuan
Xu, Weifeng
Wang, Yanhui
Zhang, Shanyong
Kim, Yong-Jin - Abstract:
- Abstract: Objective: The purpose of this study was to assess the accuracy of implant placement using surgical guide templates, and to compare the results with implant placement based on computer-aided design (CAD) planning merely. Material and methods: A total of 60 patients with dentition defects were included in our study, who were equally divided into group I and group II. Preoperative cone beam computed tomography (CBCT) was performed and preoperative planning was designed with Simplant software for all 60 patients. A total of 52 implants were placed in group I patients based on the preoperative planning without surgical guide templates. Implant surgical guide templates for group II patients were designed and produced by a rapid prototyping (RP) technique. A total of 57 implants were inserted in group II patients with the assistance of surgical templates. Postoperative CBCT was performed for all 60 patients. Image registration was carried out between postoperative CBCT data and that of preoperative planning data. Deviations of the implant between the actual and planned positions were measured and compared. Results: There was no significant structure damage during the surgery. Osseointegration was achieved in all implants, and both soft and hard tissues around implants were stable. Variation at the implant shoulder in group II was 1.18 ± 0.72 mm, apex 1.43 ± 0.74 mm, angulation 4.21 ± 1.91 mm, and depth 0.54 ± 0.29 mm, whereas the variation in group I was 2.07 ± 0.51 mmAbstract: Objective: The purpose of this study was to assess the accuracy of implant placement using surgical guide templates, and to compare the results with implant placement based on computer-aided design (CAD) planning merely. Material and methods: A total of 60 patients with dentition defects were included in our study, who were equally divided into group I and group II. Preoperative cone beam computed tomography (CBCT) was performed and preoperative planning was designed with Simplant software for all 60 patients. A total of 52 implants were placed in group I patients based on the preoperative planning without surgical guide templates. Implant surgical guide templates for group II patients were designed and produced by a rapid prototyping (RP) technique. A total of 57 implants were inserted in group II patients with the assistance of surgical templates. Postoperative CBCT was performed for all 60 patients. Image registration was carried out between postoperative CBCT data and that of preoperative planning data. Deviations of the implant between the actual and planned positions were measured and compared. Results: There was no significant structure damage during the surgery. Osseointegration was achieved in all implants, and both soft and hard tissues around implants were stable. Variation at the implant shoulder in group II was 1.18 ± 0.72 mm, apex 1.43 ± 0.74 mm, angulation 4.21 ± 1.91 mm, and depth 0.54 ± 0.29 mm, whereas the variation in group I was 2.07 ± 0.51 mm (P < 0.01), 2.89 ± 1.02 mm (P < 0.01), 8.84 ± 4.64 mm (P < 0.05), and 0.78 ± 0.33 mm (P > 0.05). Conclusion: The use of surgical guide templates can achieve higher precision and accuracy in implant shoulder, apex, and angulation, which is much more suitable for complicated procedures and conditions such as the flapless method, immediate loading, aesthetic restoration, and insufficient bone height. … (more)
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 43:Issue 10(2016:Mar.)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 43:Issue 10(2016:Mar.)
- Issue Display:
- Volume 43, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 10
- Issue Sort Value:
- 2016-0043-0010-0000
- Page Start:
- 2189
- Page End:
- 2194
- Publication Date:
- 2015-12
- Subjects:
- Dental implantation -- Computer-aided design -- Surgical guide templates -- Accuracy
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2015.10.022 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 150.xml