Mechanical quality assurance using light field for linear accelerators with camera calibration. Issue 2 (February 2016)
- Record Type:
- Journal Article
- Title:
- Mechanical quality assurance using light field for linear accelerators with camera calibration. Issue 2 (February 2016)
- Main Title:
- Mechanical quality assurance using light field for linear accelerators with camera calibration
- Authors:
- Park, Kwangwoo
Choi, Wonhoon
Keum, Ki Chang
Lee, Ho
Yoon, Jeongmin
Lee, Chang Geol
Lee, Ik Jae
Cho, Jaeho - Abstract:
- Highlights: We had performed mechanical QA using digital camera. For use of camera, calibration should be prerequisite for quantitative measurement to reduce distortions. Both camera and camera calibration provided the method for mechanical QA without loss of precisions. We suggest how to calibrate camera and how to do mechanical QA using camera. Abstract: Mechanical Quality Assurance (QA) is important to assure spatially precise delivery of external-beam radiation therapy. As an alternative to the conventional-film based method, we have developed a new tool for mechanical QA of LINACs which uses a light field rather than radiation. When light passes through the collimator, a shadow is projected onto a piece of translucent paper and the resulting image is captured by a digital camera via a mirror. With this method, we evaluated the position of the LINAC isocenter and the accuracy of the gantry, collimator, and couch rotation. We also evaluated the accuracy of the digital readouts of the gantry, collimator, and couch rotation. In addition, the treatment couch position indicator was tested. We performed camera calibration as an essential pre-requisite for quantitative measurements of the position of isocenter, the linear motion of the couch, and the rotation angles of the gantry and collimator. Camera calibration reduced the measurement error to submillimeter based on uncertainty in pixel size of the image, while, without calibration, the measurement error of up to 2 mm couldHighlights: We had performed mechanical QA using digital camera. For use of camera, calibration should be prerequisite for quantitative measurement to reduce distortions. Both camera and camera calibration provided the method for mechanical QA without loss of precisions. We suggest how to calibrate camera and how to do mechanical QA using camera. Abstract: Mechanical Quality Assurance (QA) is important to assure spatially precise delivery of external-beam radiation therapy. As an alternative to the conventional-film based method, we have developed a new tool for mechanical QA of LINACs which uses a light field rather than radiation. When light passes through the collimator, a shadow is projected onto a piece of translucent paper and the resulting image is captured by a digital camera via a mirror. With this method, we evaluated the position of the LINAC isocenter and the accuracy of the gantry, collimator, and couch rotation. We also evaluated the accuracy of the digital readouts of the gantry, collimator, and couch rotation. In addition, the treatment couch position indicator was tested. We performed camera calibration as an essential pre-requisite for quantitative measurements of the position of isocenter, the linear motion of the couch, and the rotation angles of the gantry and collimator. Camera calibration reduced the measurement error to submillimeter based on uncertainty in pixel size of the image, while, without calibration, the measurement error of up to 2 mm could occur for an object with a length of 5 cm. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 2(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 2(2016)
- Issue Display:
- Volume 32, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2016-0032-0002-0000
- Page Start:
- 398
- Page End:
- 402
- Publication Date:
- 2016-02
- Subjects:
- Camera calibration -- Light field -- Lens distortion -- Mechanical isocenter -- Quality assurance (QA)
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.01.003 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1609.xml