Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction. Issue 2 (February 2016)
- Record Type:
- Journal Article
- Title:
- Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction. Issue 2 (February 2016)
- Main Title:
- Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
- Authors:
- Gabusi, M.
Riccardi, L.
Aliberti, C.
Vio, S.
Paiusco, M. - Abstract:
- Highlights: A SSDE evaluation in Chest Computed Tomography was performed. Effective diameter was found to overestimate water-equivalent diameter up to 30%. The inaccuracy of SSDE value based on geometric size only may fluctuate considerably. Abstract: Purpose: In the setting of thorax Computed Tomography (CT), the main purpose of this work is to quantify differences in Size-Specific Dose Estimate (SSDE), calculated on the basis of both effective diameter and water-equivalent diameter, accounting for patient size and tissue attenuation, respectively. Materials and methods: An in-house software was developed to measure water-equivalent diameter and effective diameter on each CT slice, for 133 CT examinations. SSDE was calculated according to the Report of American Association of Physicists in Medicine Task Group (AAPM TG) 204 and 220. The ratio between effective and water-equivalent diameters was studied as function of cross-sectional air-to-body area ratio, for the slice located in the middle of the scan range. Results: When AAPM TG 220 prescriptions were applied, SSDE was mostly found larger than that obtained with AAPM TG 204 recommendations. On average, a difference of about 12% was observed, in spite of a considerable variability (from −18% to 53%). The ratio between effective and water-equivalent diameters ranged from 0.97 to 1.31, with a mean value of 1.15. Moreover, it was found considerably correlated with cross-sectional air-to-body ratio (Pearson's coefficient wasHighlights: A SSDE evaluation in Chest Computed Tomography was performed. Effective diameter was found to overestimate water-equivalent diameter up to 30%. The inaccuracy of SSDE value based on geometric size only may fluctuate considerably. Abstract: Purpose: In the setting of thorax Computed Tomography (CT), the main purpose of this work is to quantify differences in Size-Specific Dose Estimate (SSDE), calculated on the basis of both effective diameter and water-equivalent diameter, accounting for patient size and tissue attenuation, respectively. Materials and methods: An in-house software was developed to measure water-equivalent diameter and effective diameter on each CT slice, for 133 CT examinations. SSDE was calculated according to the Report of American Association of Physicists in Medicine Task Group (AAPM TG) 204 and 220. The ratio between effective and water-equivalent diameters was studied as function of cross-sectional air-to-body area ratio, for the slice located in the middle of the scan range. Results: When AAPM TG 220 prescriptions were applied, SSDE was mostly found larger than that obtained with AAPM TG 204 recommendations. On average, a difference of about 12% was observed, in spite of a considerable variability (from −18% to 53%). The ratio between effective and water-equivalent diameters ranged from 0.97 to 1.31, with a mean value of 1.15. Moreover, it was found considerably correlated with cross-sectional air-to-body ratio (Pearson's coefficient was 0.78 for women, 0.90 for men). Conclusion: The discrepancy obtained by calculating SSDE on the basis of AAPM TG 204, instead of AAPM TG 220 Report, may vary substantially. Fluctuations were justified by the variability observed in the relative amount of low attenuating tissues in body, which was proved to be considerably correlated to the ratio between effective and water-equivalent diameters. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 2(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 2(2016)
- Issue Display:
- Volume 32, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2016-0032-0002-0000
- Page Start:
- 393
- Page End:
- 397
- Publication Date:
- 2016-02
- Subjects:
- Computed tomography -- Water-equivalent diameter -- SSDE -- Dose
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2015.12.008 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1609.xml