Comparison of positron emission tomography diffusion‐weighted imaging (PET/DWI) registration quality in a PET/MR scanner: Zoomed DWI vs. Conventional DWI. Issue 4 (6th October 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of positron emission tomography diffusion‐weighted imaging (PET/DWI) registration quality in a PET/MR scanner: Zoomed DWI vs. Conventional DWI. Issue 4 (6th October 2015)
- Main Title:
- Comparison of positron emission tomography diffusion‐weighted imaging (PET/DWI) registration quality in a PET/MR scanner: Zoomed DWI vs. Conventional DWI
- Authors:
- Sagiyama, Koji
Watanabe, Yuji
Kamei, Ryotaro
Baba, Shingo
Honda, Hiroshi - Abstract:
- Abstract : Purpose: To compare zoomed diffusion‐weighted imaging (z‐DWI) with reduced field of view (FOV) by spatially selective radiofrequency pulses and conventional echo planar imaging (EPI) DWI (c‐DWI) with regard to registration quality using positron emission tomography / magnetic resonance (PET/MR) in patients with malignant tumors. Materials and Methods: Fludeoxyglucose (18 F ) PET imaging, c‐DWI, and z‐DWI were conducted simultaneously in 21 patients with known or suspected malignancy using a PET/MR system. A fusion image showing the largest tumor area was generated for analysis. Registration accuracy between PET and DWI was assessed based on the area of maximum overlap and central point displacement of the tumor. EPI factor, echo time (TE), matching area, and displacement were compared between c‐DWI and z‐DWI by paired t ‐test. Agreement of apparent diffusion coefficient (ADC) acquired by the two sequences were also assessed with linear regression s and Bland–Altman plot analysis. Results: Thirty‐two lesions were detected on both PET and DWI (mean size 536.3 ± 471.8 mm 2 ). At least one lesion was found in all subjects. In all cases, EPI factor was smaller with z‐DWI than c‐DWI (43.1 ± 15.6 vs. 62.0 ± 10.0, P < 0.0001), and TE was also shorter for z‐DWI (53.6 ± 3.6 msec vs. 65.2 ± 3.6 msec, P < 0.0001). Registration accuracy was better with z‐DWI in 30 of 32 lesions (93.8%), and both average matching area and central point displacement were significantly improvedAbstract : Purpose: To compare zoomed diffusion‐weighted imaging (z‐DWI) with reduced field of view (FOV) by spatially selective radiofrequency pulses and conventional echo planar imaging (EPI) DWI (c‐DWI) with regard to registration quality using positron emission tomography / magnetic resonance (PET/MR) in patients with malignant tumors. Materials and Methods: Fludeoxyglucose (18 F ) PET imaging, c‐DWI, and z‐DWI were conducted simultaneously in 21 patients with known or suspected malignancy using a PET/MR system. A fusion image showing the largest tumor area was generated for analysis. Registration accuracy between PET and DWI was assessed based on the area of maximum overlap and central point displacement of the tumor. EPI factor, echo time (TE), matching area, and displacement were compared between c‐DWI and z‐DWI by paired t ‐test. Agreement of apparent diffusion coefficient (ADC) acquired by the two sequences were also assessed with linear regression s and Bland–Altman plot analysis. Results: Thirty‐two lesions were detected on both PET and DWI (mean size 536.3 ± 471.8 mm 2 ). At least one lesion was found in all subjects. In all cases, EPI factor was smaller with z‐DWI than c‐DWI (43.1 ± 15.6 vs. 62.0 ± 10.0, P < 0.0001), and TE was also shorter for z‐DWI (53.6 ± 3.6 msec vs. 65.2 ± 3.6 msec, P < 0.0001). Registration accuracy was better with z‐DWI in 30 of 32 lesions (93.8%), and both average matching area and central point displacement were significantly improved (79.8 ± 18.1% vs. 61.8 ± 22.9%, P < 0.0001 and 3.92 ± 2.69 mm vs. 7.51 ± 4.07 mm, P < 0.0001). ADC values calculated with c‐DWI and z‐DWI showed good agreement. Conclusion: Zoomed DWI reduces image distortion and provides better registration accuracy with PET images. J. Magn. Reson. Imaging 2016;43:853–858 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 43:Issue 4(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 43:Issue 4(2016)
- Issue Display:
- Volume 43, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2016-0043-0004-0000
- Page Start:
- 853
- Page End:
- 858
- Publication Date:
- 2015-10-06
- Subjects:
- PET/MR -- image fusion -- zoomed‐EPI DWI -- spatially selective RF pulse
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25059 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2082.xml