A simple and rapid electrochemical sensing method for metribuzin determination in tap and river water samples. Issue 12 (10th March 2016)
- Record Type:
- Journal Article
- Title:
- A simple and rapid electrochemical sensing method for metribuzin determination in tap and river water samples. Issue 12 (10th March 2016)
- Main Title:
- A simple and rapid electrochemical sensing method for metribuzin determination in tap and river water samples
- Authors:
- Stojanović, Zorica
Đurović, Ana
Kravić, Snežana
Grahovac, Nada
Suturović, Zvonimir
Bursić, Vojislava
Vuković, Gorica
Brezo, Tanja - Abstract:
- Abstract : This paper describes an electroanalytical method for the determination of metribuzin using a thin film mercury electrode by chronopotentiometry. Abstract : This paper describes an electroanalytical method for the determination of metribuzin using a thin film mercury electrode by chronopotentiometry. Research included optimization of the most important parameters of chronopotentiometric analysis and the best responses were achieved in Britton–Robinson buffer at pH 5.0, using an initial potential of −0.21 V, ending potential of −1.1 V, and reduction current in the range from −4 μA to −15 μA. Under these conditions, metribuzin was reduced in an irreversible electrode reaction process with one well-defined reduction wave at −0.83 V ( vs. Ag/AgCl, KCl, 3.5 mol dm −3 ). A linear response was observed for three concentration ranges 1–5, 5–15 and 15–30 mg dm −3, with an achieved limit of detection of 0.042 mg dm −3 . The precision was determined as a function of repeatability and reproducibility, which showed relative standard deviation values not higher than 3.18%. Various interfering substances did not interfere with metribuzin determination. The proposed method was successfully applied to tap and river water samples. The recovery values obtained for spiked river water samples were in good statistical agreement with those obtained by the LC-MS/MS method. Accordingly, the proposed chronopotentiometric methodology can be conveniently applied in the quality control ofAbstract : This paper describes an electroanalytical method for the determination of metribuzin using a thin film mercury electrode by chronopotentiometry. Abstract : This paper describes an electroanalytical method for the determination of metribuzin using a thin film mercury electrode by chronopotentiometry. Research included optimization of the most important parameters of chronopotentiometric analysis and the best responses were achieved in Britton–Robinson buffer at pH 5.0, using an initial potential of −0.21 V, ending potential of −1.1 V, and reduction current in the range from −4 μA to −15 μA. Under these conditions, metribuzin was reduced in an irreversible electrode reaction process with one well-defined reduction wave at −0.83 V ( vs. Ag/AgCl, KCl, 3.5 mol dm −3 ). A linear response was observed for three concentration ranges 1–5, 5–15 and 15–30 mg dm −3, with an achieved limit of detection of 0.042 mg dm −3 . The precision was determined as a function of repeatability and reproducibility, which showed relative standard deviation values not higher than 3.18%. Various interfering substances did not interfere with metribuzin determination. The proposed method was successfully applied to tap and river water samples. The recovery values obtained for spiked river water samples were in good statistical agreement with those obtained by the LC-MS/MS method. Accordingly, the proposed chronopotentiometric methodology can be conveniently applied in the quality control of environmental water samples as a simple, sensitive, reliable and low cost method. … (more)
- Is Part Of:
- Analytical methods. Volume 8:Issue 12(2016)
- Journal:
- Analytical methods
- Issue:
- Volume 8:Issue 12(2016)
- Issue Display:
- Volume 8, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 8
- Issue:
- 12
- Issue Sort Value:
- 2016-0008-0012-0000
- Page Start:
- 2698
- Page End:
- 2705
- Publication Date:
- 2016-03-10
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c5ay03243a ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1006.xml