One-Week versus 2-Day Ventilator Circuit Change in Neonates with Prolonged Ventilation: Cost-Effectiveness and Impact on Ventilator-Associated Pneumonia. (22nd December 2014)
- Record Type:
- Journal Article
- Title:
- One-Week versus 2-Day Ventilator Circuit Change in Neonates with Prolonged Ventilation: Cost-Effectiveness and Impact on Ventilator-Associated Pneumonia. (22nd December 2014)
- Main Title:
- One-Week versus 2-Day Ventilator Circuit Change in Neonates with Prolonged Ventilation: Cost-Effectiveness and Impact on Ventilator-Associated Pneumonia
- Authors:
- Chu, Shih-Ming
Yang, Mei-Chin
Hsiao, Hsiu-Feng
Hsu, Jen-Fu
Lien, Reyin
Chiang, Ming-Chou
Fu, Ren-Huei
Huang, Hsuan-Rong
Hsu, Kuang-Hung
Tsai, Ming-Horng - Abstract:
- Abstract : Objective: To investigate the impact of 1-week ventilator circuit change on ventilator-associated pneumonia and its cost-effectiveness compared with a 2-day change. Design: An observational cohort study. Setting: A tertiary level neonatal intensive care unit in a university-affiliated teaching hospital in Taiwan. Patients: All neonates in the neonatal intensive care unit receiving invasive intubation for more than 1 week from July 1, 2011, through December 31, 2013. Intervention: We investigated the impact of 2 ventilator circuit change regimens, either every 2 days or 7 days, on ventilator-associated pneumonia of our cohort. Measurements and Main Results: A total of 361 patients were maintained on mechanical ventilators for 13, 981 days. The 2 groups did not differ significantly in any demographic characteristics. The rate of ventilator-associated pneumonia was comparable between the 2-day group and the 7-day group (8.2 vs 9.5 per 1, 000 ventilator-days, P =.439). The durations of mechanical ventilation and hospital stay, and rates of bloodstream infection and mortality, were also comparable between the 2 groups. Switching from a 2-day to a 7-day change policy would save our neonatal intensive care unit a yearly sum of US $29, 350 and 525 working hours. Conclusion: Decreasing the frequency of ventilator circuit changes from every 2 days to once per week is safe and cost-effective in neonates requiring prolonged intubation for more than 1 week. Infect Control HospAbstract : Objective: To investigate the impact of 1-week ventilator circuit change on ventilator-associated pneumonia and its cost-effectiveness compared with a 2-day change. Design: An observational cohort study. Setting: A tertiary level neonatal intensive care unit in a university-affiliated teaching hospital in Taiwan. Patients: All neonates in the neonatal intensive care unit receiving invasive intubation for more than 1 week from July 1, 2011, through December 31, 2013. Intervention: We investigated the impact of 2 ventilator circuit change regimens, either every 2 days or 7 days, on ventilator-associated pneumonia of our cohort. Measurements and Main Results: A total of 361 patients were maintained on mechanical ventilators for 13, 981 days. The 2 groups did not differ significantly in any demographic characteristics. The rate of ventilator-associated pneumonia was comparable between the 2-day group and the 7-day group (8.2 vs 9.5 per 1, 000 ventilator-days, P =.439). The durations of mechanical ventilation and hospital stay, and rates of bloodstream infection and mortality, were also comparable between the 2 groups. Switching from a 2-day to a 7-day change policy would save our neonatal intensive care unit a yearly sum of US $29, 350 and 525 working hours. Conclusion: Decreasing the frequency of ventilator circuit changes from every 2 days to once per week is safe and cost-effective in neonates requiring prolonged intubation for more than 1 week. Infect Control Hosp Epidemiol 2014;00(0): 1–7 … (more)
- Is Part Of:
- Infection control and hospital epidemiology. Volume 36:Number 3(2015)
- Journal:
- Infection control and hospital epidemiology
- Issue:
- Volume 36:Number 3(2015)
- Issue Display:
- Volume 36, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 3
- Issue Sort Value:
- 2015-0036-0003-0000
- Page Start:
- 287
- Page End:
- 293
- Publication Date:
- 2014-12-22
- Subjects:
- Nosocomial infections -- Epidemiology -- Periodicals
Health facilities -- Sanitation -- Periodicals
Hospital buildings -- Sanitation -- Periodicals
Cross Infection -- Periodicals
Epidemiology -- Periodicals
Hospitals -- Periodicals
Infection Control -- Periodicals
614.44 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00004848-000000000-00000 ↗
http://journals.cambridge.org/action/displayJournal?jid=ICE ↗
http://www.ichejournal.com/default.asp ↗
http://www.journals.uchicago.edu/ICHE/home.html ↗
http://www.jstor.org/journals/0899823X.html ↗ - DOI:
- 10.1017/ice.2014.48 ↗
- Languages:
- English
- ISSNs:
- 0899-823X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 2045.xml