A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF): a multicentre, open-label, single-arm, phase 1 trial. Issue 10025 (26th March 2016)
- Record Type:
- Journal Article
- Title:
- A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF): a multicentre, open-label, single-arm, phase 1 trial. Issue 10025 (26th March 2016)
- Main Title:
- A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF): a multicentre, open-label, single-arm, phase 1 trial
- Authors:
- Hasenfuß, Gerd
Hayward, Chris
Burkhoff, Dan
Silvestry, Frank E
McKenzie, Scott
Gustafsson, Finn
Malek, Filip
Van der Heyden, Jan
Lang, Irene
Petrie, Mark C
Cleland, John G F
Leon, Martin
Kaye, David M - Abstract:
- Summary: Background: Heart failure with preserved ejection fraction (HFPEF) is a common, globally recognised, form of heart failure for which no treatment has yet been shown to improve symptoms or prognosis. The pathophysiology of HFPEF is complex but characterised by increased left atrial pressure, especially during exertion, which might be a key therapeutic target. The rationale for the present study was that a mechanical approach to reducing left atrial pressure might be effective in HFPEF. Methods: The REDUCe Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF) study was an open-label, single-arm, phase 1 study designed to assess the performance and safety of a transcatheter interatrial shunt device (IASD, Corvia Medical, Tewkesbury, MA, USA) in patients older than 40 years of age with symptoms of HFPEF despite pharmacological therapy, left ventricular ejection fraction higher than 40%, and a raised pulmonary capillary wedge pressure at rest (>15 mm Hg) or during exercise (>25 mm Hg). The study was done at 21 centres (all departments of cardiology in the UK, Netherlands, Belgium, France, Germany, Austria, Denmark, Australia, and New Zealand). The co-primary endpoints were the safety and performance of the IASD at 6 months, together with measures of clinical efficacy, including functional capacity and clinical status, analysed per protocol. This study is registered withClinicalTrials.gov, numberNCT01913613 . Findings: Between Feb 8, 2014, and JuneSummary: Background: Heart failure with preserved ejection fraction (HFPEF) is a common, globally recognised, form of heart failure for which no treatment has yet been shown to improve symptoms or prognosis. The pathophysiology of HFPEF is complex but characterised by increased left atrial pressure, especially during exertion, which might be a key therapeutic target. The rationale for the present study was that a mechanical approach to reducing left atrial pressure might be effective in HFPEF. Methods: The REDUCe Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF) study was an open-label, single-arm, phase 1 study designed to assess the performance and safety of a transcatheter interatrial shunt device (IASD, Corvia Medical, Tewkesbury, MA, USA) in patients older than 40 years of age with symptoms of HFPEF despite pharmacological therapy, left ventricular ejection fraction higher than 40%, and a raised pulmonary capillary wedge pressure at rest (>15 mm Hg) or during exercise (>25 mm Hg). The study was done at 21 centres (all departments of cardiology in the UK, Netherlands, Belgium, France, Germany, Austria, Denmark, Australia, and New Zealand). The co-primary endpoints were the safety and performance of the IASD at 6 months, together with measures of clinical efficacy, including functional capacity and clinical status, analysed per protocol. This study is registered withClinicalTrials.gov, numberNCT01913613 . Findings: Between Feb 8, 2014, and June 10, 2015, 68 eligible patients were entered into the study. IASD placement was successful in 64 patients and seemed to be safe and well tolerated; no patient had a peri-procedural or major adverse cardiac or cerebrovascular event or need for cardiac surgical intervention for device-related complications during 6 months of follow-up. At 6 months, 31 (52%) of 60 patients had a reduction in pulmonary capillary wedge pressure at rest, 34 (58%) of 59 had a lower pulmonary capillary wedge pressure during exertion, and 23 (39%) of 59 fulfilled both these criteria. Mean exercise pulmonary capillary wedge pressure was lower at 6 months than at baseline, both at 20 watts workload (mean 32 mm Hg [SD 8] at baseline vs 29 mm Hg [9] at 6 months, p=0·0124) and at peak exercise (34 mm Hg [8] vs 32 [8], p=0·0255), despite increased mean exercise duration (baseline vs 6 months: 7·3 min [SD 3·1] vs 8·2 min [3·4], p=0·03). Sustained device patency at 6 months was confirmed by left-to-right shunting (pulmonary/systemic flow ratio: 1·06 [SD 0·32] at baseline vs 1·27 [0·20] at 6 months, p=0·0004). Interpretation: Implantation of an interatrial shunt device is feasible, seems to be safe, reduces left atrial pressure during exercise, and could be a new strategy for the management of HFPEF. The effectiveness of IASD compared with existing treatment for patients with HFPEF requires validation in a randomised controlled trial. Funding: Corvia Medical Inc. … (more)
- Is Part Of:
- Lancet. Volume 387:Issue 10025(2016)
- Journal:
- Lancet
- Issue:
- Volume 387:Issue 10025(2016)
- Issue Display:
- Volume 387, Issue 10025 (2016)
- Year:
- 2016
- Volume:
- 387
- Issue:
- 10025
- Issue Sort Value:
- 2016-0387-10025-0000
- Page Start:
- 1298
- Page End:
- 1304
- Publication Date:
- 2016-03-26
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Medicine
Electronic journals
Periodicals
610.5 - Journal URLs:
- http://www.thelancet.com/ ↗
http://www.sciencedirect.com/science/journal/01406736 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/S0140-6736(16)00704-2 ↗
- Languages:
- English
- ISSNs:
- 0140-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5146.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 631.xml