An efficient level set method for simultaneous intensity inhomogeneity correction and segmentation of MR images. (March 2016)
- Record Type:
- Journal Article
- Title:
- An efficient level set method for simultaneous intensity inhomogeneity correction and segmentation of MR images. (March 2016)
- Main Title:
- An efficient level set method for simultaneous intensity inhomogeneity correction and segmentation of MR images
- Authors:
- Ivanovska, Tatyana
Laqua, René
Wang, Lei
Schenk, Andrea
Yoon, Jeong Hee
Hegenscheid, Katrin
Völzke, Henry
Liebscher, Volkmar - Abstract:
- Abstract : Highlights: We propose a novel method for simultaneous intensity inhomogeneity correction and segmentation. Energy functional includes total variation regularization for bias field and level set function. The minimization procedure searches the global minimum and does not depend on initialization. The method was tested on synthetic and real images and evaluated qualitatively and quantitatively. The approach produces results, similar or superior in quality compared to other techniques. Abstract: Intensity inhomogeneity (bias field) is a common artefact in magnetic resonance (MR) images, which hinders successful automatic segmentation. In this work, a novel algorithm for simultaneous segmentation and bias field correction is presented. The proposed energy functional allows for explicit regularization of the bias field term, making the model more flexible, which is crucial in presence of strong inhomogeneities. An efficient minimization procedure, attempting to find the global minimum, is applied to the energy functional. The algorithm is evaluated qualitatively and quantitatively using a synthetic example and real MR images of different organs. Comparisons with several state-of-the-art methods demonstrate the superior performance of the proposed technique. Desirable results are obtained even for images with strong and complicated inhomogeneity fields and sparse tissue structures.
- Is Part Of:
- Computerized medical imaging and graphics. Volume 48(2016)
- Journal:
- Computerized medical imaging and graphics
- Issue:
- Volume 48(2016)
- Issue Display:
- Volume 48, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 48
- Issue:
- 2016
- Issue Sort Value:
- 2016-0048-2016-0000
- Page Start:
- 9
- Page End:
- 20
- Publication Date:
- 2016-03
- Subjects:
- MRI -- Segmentation -- Bias field -- Intensity inhomogeneity -- Level set
Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnosis, Radioscopic -- Data processing -- Periodicals
Diagnostic Imaging -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Diagnostic imaging
Periodicals
Electronic journals
Electronic journals
616.0754 - Journal URLs:
- http://www.journals.elsevier.com/computerized-medical-imaging-and-graphics/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compmedimag.2015.11.005 ↗
- Languages:
- English
- ISSNs:
- 0895-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2477.xml