Thomas, Daniel K. - Abstract:
- Abstract : Purpose: To investigate whether cardiac magnetic resonance (cardiac MR)‐based feature tracking (FT) may be used for robust and rapid quantification of dyssynchrony by measurement of the septal to lateral delay (SLD). Materials and Methods: Healthy volunteers ( n = 18) and patients with mechanical dyssynchrony ( n = 17) were investigated. Velocity encoding cardiac MR (VENC) and steady‐state free precession (SSFP)‐cine sequences were acquired in identical horizontal long axis (HLA) positions using a 1.5T MR scanner. Using FT and VENC cardiac MR software, myocardial velocity curves were calculated for the basal segment of the septal and lateral wall. Based on the quantity of dyssynchrony, the patients were classified into three subgroups (minimal, intermediate, extensive). SLD and patient classification were compared and intra‐ as well as interobserver variability assessed. Results: VENC and FT SLD measurements showed strong correlation ( r = 0.94) and good agreement (mean 1.33 msec; limits of agreement [LoA] −2.96 to 5.63). Dyssynchrony subclassification based on FT was identical to VENC in 83% of the cases. While FT correctly classified all healthy subjects, three patients with mechanical dyssynchrony were misclassified. Compared to VENC, FT showed higher intra‐ and interobserver variability. VENC: intraobserver: mean 2.5 msec, LoA −17.5 to 22.5; interobserver: mean 1.5 msec, LoA −17.2 to 21.9. FT: intraobserver: mean 2.1 msec, LoA 27.6 to 31.8; interobserver: meanAbstract : Purpose: To investigate whether cardiac magnetic resonance (cardiac MR)‐based feature tracking (FT) may be used for robust and rapid quantification of dyssynchrony by measurement of the septal to lateral delay (SLD). Materials and Methods: Healthy volunteers ( n = 18) and patients with mechanical dyssynchrony ( n = 17) were investigated. Velocity encoding cardiac MR (VENC) and steady‐state free precession (SSFP)‐cine sequences were acquired in identical horizontal long axis (HLA) positions using a 1.5T MR scanner. Using FT and VENC cardiac MR software, myocardial velocity curves were calculated for the basal segment of the septal and lateral wall. Based on the quantity of dyssynchrony, the patients were classified into three subgroups (minimal, intermediate, extensive). SLD and patient classification were compared and intra‐ as well as interobserver variability assessed. Results: VENC and FT SLD measurements showed strong correlation ( r = 0.94) and good agreement (mean 1.33 msec; limits of agreement [LoA] −2.96 to 5.63). Dyssynchrony subclassification based on FT was identical to VENC in 83% of the cases. While FT correctly classified all healthy subjects, three patients with mechanical dyssynchrony were misclassified. Compared to VENC, FT showed higher intra‐ and interobserver variability. VENC: intraobserver: mean 2.5 msec, LoA −17.5 to 22.5; interobserver: mean 1.5 msec, LoA −17.2 to 21.9. FT: intraobserver: mean 2.1 msec, LoA 27.6 to 31.8; interobserver: mean 2.4 msec LoA −31.4 to 34.5. Conclusion: Cardiac MR‐based FT analysis may be used for rapid appraisal of left ventricle cardiac dyssynchrony from SSFP images. However, FT results are less accurate and reproducible compared to VENC‐based assessment of SLD. J. Magn. Reson. Imaging 2016;43:940–946 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 43:Issue 4(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 43:Issue 4(2016)
- Issue Display:
- Volume 43, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2016-0043-0004-0000
- Page Start:
- 940
- Page End:
- 946
- Publication Date:
- 2015-10-01
- Subjects:
- dyssynchrony -- septal to lateral delay -- feature tracking -- CRT
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25062 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2082.xml