Effect of immediate and delayed dentin sealing on the fracture strength, failure type and Weilbull characteristics of lithiumdisilicate laminate veneers. Issue 4 (April 2016)
- Record Type:
- Journal Article
- Title:
- Effect of immediate and delayed dentin sealing on the fracture strength, failure type and Weilbull characteristics of lithiumdisilicate laminate veneers. Issue 4 (April 2016)
- Main Title:
- Effect of immediate and delayed dentin sealing on the fracture strength, failure type and Weilbull characteristics of lithiumdisilicate laminate veneers
- Authors:
- Gresnigt, Marco M.M.
Cune, Marco S.
de Roos, Joanne G.
Özcan, Mutlu - Abstract:
- Abstract: Objectives: Adhesion on dentin is less reliable than on enamel, which could affect the durability of laminate veneers (LV). Immediate dentin sealing (IDS) is suggested instead of delayed dentin sealing (DDS) to overcome hypersensitivity and prevent debonding from dentin. This study evaluated the effect of IDS and DDS on the durability of Li2 Si2 O5 laminate veneers in vitro. Methods: Window preparations were made on the labial surfaces of sound maxillary central incisors ( N = 50). They were randomly divided into five groups: Group 1: Enamel only + H3 PO4 + Adhesive (control); Group 2: <1/4 dentin + H3 PO4 + DDS (2 weeks later); Group 3: Complete dentin + H3 PO4 + DDS (2 weeks later); Group 4: <1/4 dentin + H3 PO4 + IDS; Group 5: Complete dentin + H3 PO4 + IDS. Li2 Si2 O5 laminate veneers (e.max Press) were bonded to the labial surfaces of the teeth with adhesive resin cement (Variolink Veneer). IDS layers were silicacoated (CoJet System) and silanized (ESPE-Sil). The teeth with their bonded laminates were thermocycled (10.000× cycles) and then subjected to static loading (1 mm/min). Failure type and location after debonding were classified. Data were analyzed using ANOVA and Tukey's post hoc test ( α = 0.05). Two-parameter Weibull distribution values including the Weibull modulus, scale ( m ) and shape (0 ), values were calculated. Results: Mean fracture strength ( N ) per group in descending order was as follows: Group 5 (576 ± 254), Group 4 (478 ± 216),Abstract: Objectives: Adhesion on dentin is less reliable than on enamel, which could affect the durability of laminate veneers (LV). Immediate dentin sealing (IDS) is suggested instead of delayed dentin sealing (DDS) to overcome hypersensitivity and prevent debonding from dentin. This study evaluated the effect of IDS and DDS on the durability of Li2 Si2 O5 laminate veneers in vitro. Methods: Window preparations were made on the labial surfaces of sound maxillary central incisors ( N = 50). They were randomly divided into five groups: Group 1: Enamel only + H3 PO4 + Adhesive (control); Group 2: <1/4 dentin + H3 PO4 + DDS (2 weeks later); Group 3: Complete dentin + H3 PO4 + DDS (2 weeks later); Group 4: <1/4 dentin + H3 PO4 + IDS; Group 5: Complete dentin + H3 PO4 + IDS. Li2 Si2 O5 laminate veneers (e.max Press) were bonded to the labial surfaces of the teeth with adhesive resin cement (Variolink Veneer). IDS layers were silicacoated (CoJet System) and silanized (ESPE-Sil). The teeth with their bonded laminates were thermocycled (10.000× cycles) and then subjected to static loading (1 mm/min). Failure type and location after debonding were classified. Data were analyzed using ANOVA and Tukey's post hoc test ( α = 0.05). Two-parameter Weibull distribution values including the Weibull modulus, scale ( m ) and shape (0 ), values were calculated. Results: Mean fracture strength ( N ) per group in descending order was as follows: Group 5 (576 ± 254), Group 4 (478 ± 216), Group 1 (473 ± 159), Group 2 (465 ± 186), and Group 3 (314 ± 137). The presence of complete dentin exposure sealed with DDS after 2 weeks on the bonded surface (Group 3) resulted in significantly lower fracture strength results than those in group 5 with IDS ( p = 0.034). Weibull distribution presented higher shape (0 ) for Group 1 (3.67), than those of other groups (2.51–2.89). Failure types were predominantly adhesive failure between the cement and the laminate veneer in Groups 1, 2, 4 whereas Group 3 presented more often complete adhesive failures between the cement and dentin. In Group 5, failures showed some IDS and cement with or without ceramic fracture attached on the tooth. Significance: When laminate veneers are bonded to a large dentin substrate, application of immediate dentin sealing improves adhesion and thereby, the fracture strength of Li2 Si2 O5 laminate veneers. … (more)
- Is Part Of:
- Dental materials. Volume 32:Issue 4(2016)
- Journal:
- Dental materials
- Issue:
- Volume 32:Issue 4(2016)
- Issue Display:
- Volume 32, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2016-0032-0004-0000
- Page Start:
- e73
- Page End:
- e81
- Publication Date:
- 2016-04
- Subjects:
- Adhesion -- Bonding -- Cementation -- Ceramic -- Dentin -- Immediate dentin sealing -- Laminate -- Veneer
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2016.01.001 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1151.xml