Accuracy and reproducibility of linear measurements of resin, plaster, digital and printed study-models. (December 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy and reproducibility of linear measurements of resin, plaster, digital and printed study-models. (December 2015)
- Main Title:
- Accuracy and reproducibility of linear measurements of resin, plaster, digital and printed study-models
- Authors:
- Saleh, Waleed K.
Ariffin, Emy
Sherriff, Martyn
Bister, Dirk - Abstract:
- Abstract : Objectives: : To compare the accuracy and reproducibility of measurements of on-screen three-dimensional (3D) digital surface models captured by a 3Shape R700™ laser-scanner, with measurements made using a digital caliper on acrylic, plaster models or model replicas.Subjects and Method: : Four sets of typodont models were used. Acrylic models, alginate impressions, plaster models and physical replicas were measured. The 3Shape R700™ laser-scanning device with 3Shape™ software was used for scans and measurements. Linear measurements were recorded for selected landmarks, on each of the physical models and on the 3D digital surface models on ten separate occasions by a single examiner.Results: : Comparing measurements taken on the physical models the mean difference of the measurements was 0.32 mm (SD 0.15 mm). For the different methods (physical versus digital) the mean difference was 0.112 mm (SD 0.15 mm). None of the values showed a statistically significant difference ( p < 0.05) on the Objet Eden 250™ 3D prints, alginate impressions, plaster and acrylic models.Conclusion: : The comparison of measurements on the physical models showed no significant difference. The 3Shape R700™ is a reliable device for capturing surface details of models in a digital format. When comparing measurements taken manually and digitally there was no statistically significant difference. The Objet Eden 250™ 3D prints proved to be as accurate as the original acrylic, plaster, orAbstract : Objectives: : To compare the accuracy and reproducibility of measurements of on-screen three-dimensional (3D) digital surface models captured by a 3Shape R700™ laser-scanner, with measurements made using a digital caliper on acrylic, plaster models or model replicas.Subjects and Method: : Four sets of typodont models were used. Acrylic models, alginate impressions, plaster models and physical replicas were measured. The 3Shape R700™ laser-scanning device with 3Shape™ software was used for scans and measurements. Linear measurements were recorded for selected landmarks, on each of the physical models and on the 3D digital surface models on ten separate occasions by a single examiner.Results: : Comparing measurements taken on the physical models the mean difference of the measurements was 0.32 mm (SD 0.15 mm). For the different methods (physical versus digital) the mean difference was 0.112 mm (SD 0.15 mm). None of the values showed a statistically significant difference ( p < 0.05) on the Objet Eden 250™ 3D prints, alginate impressions, plaster and acrylic models.Conclusion: : The comparison of measurements on the physical models showed no significant difference. The 3Shape R700™ is a reliable device for capturing surface details of models in a digital format. When comparing measurements taken manually and digitally there was no statistically significant difference. The Objet Eden 250™ 3D prints proved to be as accurate as the original acrylic, plaster, or alginate impressions as was shown by the accuracy of the measurements taken. This confirms that using virtual study models can be a reliable method, replacing traditional plaster models. … (more)
- Is Part Of:
- Journal of orthodontics. Volume 42:Number 4(2015:Dec.)
- Journal:
- Journal of orthodontics
- Issue:
- Volume 42:Number 4(2015:Dec.)
- Issue Display:
- Volume 42, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2015-0042-0004-0000
- Page Start:
- 301
- Page End:
- 306
- Publication Date:
- 2015-12
- Subjects:
- 3Shape R700™ -- Objet Eden250™ -- 3Shape Ortho Analyzer™ -- rapid prototyping -- stereolithography
Orthodontics -- Periodicals
617.643005 - Journal URLs:
- http://jorthod.maneyjournals.org/content/by/year ↗
http://www.tandfonline.com/toc/yjor20/current ↗
https://journals.sagepub.com/home/joo ↗
http://maneypublishing.com/ ↗
http://ortho.oupjournals.org ↗ - DOI:
- 10.1179/1465313315Y.0000000016 ↗
- Languages:
- English
- ISSNs:
- 1465-3125
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1424.xml