Non-invasive estimation of pulmonary outflow tract obstruction: A comparative study of cardiovascular phase contrast magnetic resonance and Doppler echocardiography versus cardiac catheterization. (March 2016)
- Record Type:
- Journal Article
- Title:
- Non-invasive estimation of pulmonary outflow tract obstruction: A comparative study of cardiovascular phase contrast magnetic resonance and Doppler echocardiography versus cardiac catheterization. (March 2016)
- Main Title:
- Non-invasive estimation of pulmonary outflow tract obstruction: A comparative study of cardiovascular phase contrast magnetic resonance and Doppler echocardiography versus cardiac catheterization
- Authors:
- Kowallick, Johannes Tammo
Steinmetz, Michael
Schuster, Andreas
Unterberg-Buchwald, Christina
Nguyen, Thuy-Trang
Fasshauer, Martin
Staab, Wieland
Hösch, Olga
Rosenberg, Christina
Paul, Thomas
Lotz, Joachim
Sohns, Jan Martin - Abstract:
- Abstract: Aim: To compare estimated pressure gradients from routine follow-up cardiovascular phase-contrast magnetic resonance (PC-MR) with those from Doppler echocardiography and invasive catheterization in patients with congenital heart disease (CHD) and pulmonary outflow tract obstruction. Methods: In 75 patients with pulmonary outflow tract obstruction maximal and mean PC-MR gradients were compared to maximal and mean Doppler gradients. Additionally, in a subgroup of 31 patients maximal and mean PC-MR and Doppler pressure gradients were compared to catheter peak-to-peak pressure gradients (PPG). Results: Maximal and mean PC-MR gradients underestimated pulmonary outflow tract obstruction as compared to Doppler (max gradient: bias = + 8.4 mm Hg (+ 47.6%), r = 0.89, p < 0.001; mean gradient: + 4.3 mm Hg (+ 49.0%), r = 0.88, p < 0.001). However, in comparison to catheter PPG, maximal PC-MR gradients (bias = + 1.8 mm Hg (+ 8.8%), r = 0.90, p = 0.14) and mean Doppler gradients (bias = − 2.3 mm Hg (− 11.2%), r = 0.87, p = 0.17) revealed best agreement. Mean PC-MR gradients underestimated (bias = − 7.7 mm Hg (− 55.6%), r = 0.90, p < 0.001) while maximal Doppler gradients systematically overestimated catheter PPG (bias = + 13.9 mm Hg (+ 56.5%), r = 0.88, p < 0.001). Conclusions: Estimated maximal PC-MR pressure gradients from routine CHD follow-up agree well with invasively assessed peak-to-peak pressure gradients. Estimated maximal Doppler pressure gradients tend toAbstract: Aim: To compare estimated pressure gradients from routine follow-up cardiovascular phase-contrast magnetic resonance (PC-MR) with those from Doppler echocardiography and invasive catheterization in patients with congenital heart disease (CHD) and pulmonary outflow tract obstruction. Methods: In 75 patients with pulmonary outflow tract obstruction maximal and mean PC-MR gradients were compared to maximal and mean Doppler gradients. Additionally, in a subgroup of 31 patients maximal and mean PC-MR and Doppler pressure gradients were compared to catheter peak-to-peak pressure gradients (PPG). Results: Maximal and mean PC-MR gradients underestimated pulmonary outflow tract obstruction as compared to Doppler (max gradient: bias = + 8.4 mm Hg (+ 47.6%), r = 0.89, p < 0.001; mean gradient: + 4.3 mm Hg (+ 49.0%), r = 0.88, p < 0.001). However, in comparison to catheter PPG, maximal PC-MR gradients (bias = + 1.8 mm Hg (+ 8.8%), r = 0.90, p = 0.14) and mean Doppler gradients (bias = − 2.3 mm Hg (− 11.2%), r = 0.87, p = 0.17) revealed best agreement. Mean PC-MR gradients underestimated (bias = − 7.7 mm Hg (− 55.6%), r = 0.90, p < 0.001) while maximal Doppler gradients systematically overestimated catheter PPG (bias = + 13.9 mm Hg (+ 56.5%), r = 0.88, p < 0.001). Conclusions: Estimated maximal PC-MR pressure gradients from routine CHD follow-up agree well with invasively assessed peak-to-peak pressure gradients. Estimated maximal Doppler pressure gradients tend to overestimate, while Doppler mean gradients agree better with catheter PPG. Therefore, our data provide reasonable arguments to either apply maximal PC-MR gradients or mean Doppler gradients to non-invasively evaluate the severity of pulmonary outflow tract obstruction in the follow-up of CHD. … (more)
- Is Part Of:
- IJC heart & vasculature. Volume 10(2016)
- Journal:
- IJC heart & vasculature
- Issue:
- Volume 10(2016)
- Issue Display:
- Volume 10, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 2016
- Issue Sort Value:
- 2016-0010-2016-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2016-03
- Subjects:
- Pulmonary outflow tract obstruction -- Congenital heart disease -- MR phase-contrast flow -- Doppler echocardiography -- Catheterization -- Pressure gradient
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular system -- Pathophysiology -- Periodicals
616.1005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23529067/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ijcha.2015.11.001 ↗
- Languages:
- English
- ISSNs:
- 2352-9067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1369.xml