A Micromechanical Cantilever‐Based Liposome Biosensor for Characterization of Protein‐Membrane Interaction. Issue 3 (23rd September 2015)
- Record Type:
- Journal Article
- Title:
- A Micromechanical Cantilever‐Based Liposome Biosensor for Characterization of Protein‐Membrane Interaction. Issue 3 (23rd September 2015)
- Main Title:
- A Micromechanical Cantilever‐Based Liposome Biosensor for Characterization of Protein‐Membrane Interaction
- Authors:
- Zhang, Z.
Sohgawa, M.
Yamashita, K.
Noda, M. - Abstract:
- Abstract: We have newly evaluated the interaction of lipid membrane with two different proteins of lysozyme and carbonic anhydrase from bovine (CAB) using a micro cantilever‐based liposome biosensor with a new droplet‐sealing structure. Herein 1, 2‐dipalmitoyl‐sn‐glycero‐3‐phosphocholine (DPPC) liposomes are used as model lipid membrane and are immobilized on the surface of cantilever. The interaction of DPPC liposome with the target protein causes deflection of the micro‐cantilever, which can stably be detected by measuring the resistance change of the strain gauge. The resistance change dependent on time is used to evaluate the characteristic of liposome‐protein interaction. The resistance of the cantilever‐based biosensor increases monotonously with time in both of the two protein solutions. Especially, chronological resistance change depends markedly on both the concentration and species of target proteins. Finally, these results lead us to conclude that the cantilever‐based liposome biosensor with the droplet‐sealing structure facilitates the characterization of protein‐membrane interaction. It also means that this biosensor is a promising candidate device for label‐free detection of concentration and species of different target proteins. Abstract :
- Is Part Of:
- Electroanalysis. Volume 28:Issue 3(2016)
- Journal:
- Electroanalysis
- Issue:
- Volume 28:Issue 3(2016)
- Issue Display:
- Volume 28, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 28
- Issue:
- 3
- Issue Sort Value:
- 2016-0028-0003-0000
- Page Start:
- 620
- Page End:
- 625
- Publication Date:
- 2015-09-23
- Subjects:
- Cantilever -- Biosensor -- Liposome -- Protein -- Interaction -- Droplet‐sealing structure
Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.201500412 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 791.xml