Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets. Issue 4 (April 2016)
- Record Type:
- Journal Article
- Title:
- Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets. Issue 4 (April 2016)
- Main Title:
- Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets
- Authors:
- De Cecco, Carlo N.
Caruso, Damiano
Schoepf, U. Joseph
Wichmann, Julian L.
Ter Louw, Janet R.
Perry, Jonathan D.
Picard, Melissa M.
Schaefer, Amanda R.
Parker, Leland W.
Hardie, Andrew D. - Abstract:
- Highlights: M70 and M50+ keV monoenergetic images show higher contrast attenuation than LB120, which may affect window settings. Arterial and portal M50+ optimal liver W/L is significantly higher than LB120. Dedicated M50+ W/L improves liver lesion detection rates compared to LB120 W/L. Abstract: Objectives: To evaluate optimal window settings for display of virtual monoenergetic reconstructions in third-generation dual-source, dual-energy computed tomography (DECT) of the liver. Methods: Twenty-nine subjects were prospectively evaluated with DECT in arterial (AP) and portal venous (PVP) phases. Three reconstructed datasets were calculated: standard linearly-blended (LB120), 70-keV standard virtual monoenergetic (M70), and 50-keV advanced image-based virtual monoenergetic (M50+). Two readers assessed optimal window settings (width and level, W/L), establishing a mean for each reconstruction which was used for a blinded assessment of liver lesions. Results: The optimal W/L for M50+ were significantly higher for both AP (W = 429.3 ± 44.6HU, L = 129.4 ± 9.7HU) and PVP ( W = 376.1 ± 14.2HU, L = 146.6 ± 7.0HU) than for LB120 (AP, W = 215.9 ± 16.9HU, L = 82.3 ± 9.4HU) (PVP, W = 173.4 ± 8.9HU, L = 69.3 ± 6.0HU) and M70 (AP, W = 247.1 ± 22.2HU, L = 72.9 ± 6.8HU) (PVP, W = 232.0 ± 27.9HU, L = 91.6 ± 14.4HU). Use of the optimal window setting for M50+ vs. LB120 resulted in higher sensitivity (AP, 100% vs. 86%; PVP, 96% vs. 63%). Conclusions: Application of dedicated windowHighlights: M70 and M50+ keV monoenergetic images show higher contrast attenuation than LB120, which may affect window settings. Arterial and portal M50+ optimal liver W/L is significantly higher than LB120. Dedicated M50+ W/L improves liver lesion detection rates compared to LB120 W/L. Abstract: Objectives: To evaluate optimal window settings for display of virtual monoenergetic reconstructions in third-generation dual-source, dual-energy computed tomography (DECT) of the liver. Methods: Twenty-nine subjects were prospectively evaluated with DECT in arterial (AP) and portal venous (PVP) phases. Three reconstructed datasets were calculated: standard linearly-blended (LB120), 70-keV standard virtual monoenergetic (M70), and 50-keV advanced image-based virtual monoenergetic (M50+). Two readers assessed optimal window settings (width and level, W/L), establishing a mean for each reconstruction which was used for a blinded assessment of liver lesions. Results: The optimal W/L for M50+ were significantly higher for both AP (W = 429.3 ± 44.6HU, L = 129.4 ± 9.7HU) and PVP ( W = 376.1 ± 14.2HU, L = 146.6 ± 7.0HU) than for LB120 (AP, W = 215.9 ± 16.9HU, L = 82.3 ± 9.4HU) (PVP, W = 173.4 ± 8.9HU, L = 69.3 ± 6.0HU) and M70 (AP, W = 247.1 ± 22.2HU, L = 72.9 ± 6.8HU) (PVP, W = 232.0 ± 27.9HU, L = 91.6 ± 14.4HU). Use of the optimal window setting for M50+ vs. LB120 resulted in higher sensitivity (AP, 100% vs. 86%; PVP, 96% vs. 63%). Conclusions: Application of dedicated window settings results in improved liver lesion detection rates in advanced image-based virtual monoenergetic DECT when customized for arterial and portal venous phases. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 4(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 4(2016)
- Issue Display:
- Volume 85, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 4
- Issue Sort Value:
- 2016-0085-0004-0000
- Page Start:
- 695
- Page End:
- 699
- Publication Date:
- 2016-04
- Subjects:
- VMI virtual monoenergetic imaging -- VMI+ advanced image-based monoenergetic algorithm -- LB120 Standard linearly-blended -- M70 70-keV standard monoenergetic -- M50+ 50-keV advanced image-based virtual monoenergetic
Dual Energy CT -- Monoenergetic -- Liver -- Hepatocellular carcinoma -- Window
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.01.007 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1102.xml