Acute myocardial infarction: susceptibility-weighted cardiac MRI for the detection of reperfusion haemorrhage at 1.5 T. Issue 3 (March 2016)
- Record Type:
- Journal Article
- Title:
- Acute myocardial infarction: susceptibility-weighted cardiac MRI for the detection of reperfusion haemorrhage at 1.5 T. Issue 3 (March 2016)
- Main Title:
- Acute myocardial infarction: susceptibility-weighted cardiac MRI for the detection of reperfusion haemorrhage at 1.5 T
- Authors:
- Durighel, G.
Tokarczuk, P.F.
Karsa, A.
Gordon, F.
Cook, S.A.
O'Regan, D.P. - Abstract:
- Abstract : Aim: To assess whether susceptibility-weighted imaging (SWI) provides better image contrast for the detection of haemorrhagic ischaemia–reperfusion injury in the heart. Materials and methods: Thirty patients (all men; mean age 53 years) underwent cardiac magnetic resonance imaging (MRI) within 7 days of primary percutaneous intervention for acute ST elevation myocardial infarction (STEMI). Multiple gradient-echo T2* sequences with magnitude and phase reconstructions were acquired. A high-pass filtered phase map was used to create a mask for the SWI reconstructions. The difference in image contrast was assessed in those patients with microvascular obstruction. A mixed effects regression model was used to test the effect of echo time and reconstruction method on phase and contrast-to-noise ratio (CNR). Medians and interquartile ranges (IQR) are reported. Results: T2* in haemorrhagic infarcts was shorter than in non-haemorrhagic infarcts (33.5 ms [24.9–43] versus 49.9 ms [44.6–67.6]; p =0.0007). The effect of echo time on phase was significant ( p <0.0001), as was the effect of haemorrhage on phase ( p =0.0016). SWI reconstruction had a significant effect on the CNR at all echo times (echoes 1–5, p <0.0001; echo 6, p =0.01; echo 7, p =0.02). The median echo number at which haemorrhage was first visible was less for SWI compared to source images (echo 2 versus echo 5, p =0.0002). Conclusion: Cardiac SWI improves the contrast between myocardial haemorrhage and theAbstract : Aim: To assess whether susceptibility-weighted imaging (SWI) provides better image contrast for the detection of haemorrhagic ischaemia–reperfusion injury in the heart. Materials and methods: Thirty patients (all men; mean age 53 years) underwent cardiac magnetic resonance imaging (MRI) within 7 days of primary percutaneous intervention for acute ST elevation myocardial infarction (STEMI). Multiple gradient-echo T2* sequences with magnitude and phase reconstructions were acquired. A high-pass filtered phase map was used to create a mask for the SWI reconstructions. The difference in image contrast was assessed in those patients with microvascular obstruction. A mixed effects regression model was used to test the effect of echo time and reconstruction method on phase and contrast-to-noise ratio (CNR). Medians and interquartile ranges (IQR) are reported. Results: T2* in haemorrhagic infarcts was shorter than in non-haemorrhagic infarcts (33.5 ms [24.9–43] versus 49.9 ms [44.6–67.6]; p =0.0007). The effect of echo time on phase was significant ( p <0.0001), as was the effect of haemorrhage on phase ( p =0.0016). SWI reconstruction had a significant effect on the CNR at all echo times (echoes 1–5, p <0.0001; echo 6, p =0.01; echo 7, p =0.02). The median echo number at which haemorrhage was first visible was less for SWI compared to source images (echo 2 versus echo 5, p =0.0002). Conclusion: Cardiac SWI improves the contrast between myocardial haemorrhage and the surrounding tissue following STEMI and has potential as a new tool for identifying patients with ischaemia–reperfusion injury. Highlights: Cardiac susceptibility-weighted imaging (SWI) is feasible at 1.5T. Combining phase and modulus data allows blood products to be seen at shorter echo times. This sequence improves visualisation of reperfusion myocardial haemorrhage. … (more)
- Is Part Of:
- Clinical radiology. Volume 71:Issue 3(2016)
- Journal:
- Clinical radiology
- Issue:
- Volume 71:Issue 3(2016)
- Issue Display:
- Volume 71, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 71
- Issue:
- 3
- Issue Sort Value:
- 2016-0071-0003-0000
- Page Start:
- e150
- Page End:
- e156
- Publication Date:
- 2016-03
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2015.12.008 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 168.xml