Accuracy of a flapless protocol for computer‐guided zygomatic implant placement in human cadavers: expectations and reality. Issue 1 (27th January 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy of a flapless protocol for computer‐guided zygomatic implant placement in human cadavers: expectations and reality. Issue 1 (27th January 2015)
- Main Title:
- Accuracy of a flapless protocol for computer‐guided zygomatic implant placement in human cadavers: expectations and reality
- Authors:
- Schiroli, Guido
Angiero, Francesca
Zangerl, Antoniettel
Benedicenti, Stefano
Ferrante, Franco
Widmann, Gerlig - Abstract:
- Abstract: Background: This work evaluated the accuracy and safety of a protocol for minimally‐invasive flapless zygomatic implant placement that uses computer‐guided stereolithographic mucosa‐supported surgical templates. Methods: A total of six zygomatic implants were placed in three formalin‐fixed human cadaver heads, with edentulous and severely atrophic posterior maxillae. CT scans of each cadaver head were performed after zygomatic implant placement, to evaluate the lateral error (LE) at implant tip and base, and the angular error (AE) of the implant body. Results: Excluding the implant placed outside the drilling channel, the LE at the implant base was less than 1 mm in all cases. The average LE at the tip was 3.86 mm, and the AE was less than 6° in all cases, with an average of 4.5°. Conclusion: Computer‐guided minimally‐invasive flapless zygomatic implant surgery remains challenging. Careful planning and perfect stability of the surgical guide are essential. Copyright © 2015 John Wiley & Sons, Ltd.
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 12:Issue 1(2016)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 12:Issue 1(2016)
- Issue Display:
- Volume 12, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 12
- Issue:
- 1
- Issue Sort Value:
- 2016-0012-0001-0000
- Page Start:
- 102
- Page End:
- 108
- Publication Date:
- 2015-01-27
- Subjects:
- zygomatic implant -- flapless protocol
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.1646 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: