Consistency in Administration and Response for the Backward Push and Release Test: A Clinical Assessment of Postural Responses. (28th November 2014)
- Record Type:
- Journal Article
- Title:
- Consistency in Administration and Response for the Backward Push and Release Test: A Clinical Assessment of Postural Responses. (28th November 2014)
- Main Title:
- Consistency in Administration and Response for the Backward Push and Release Test: A Clinical Assessment of Postural Responses
- Authors:
- Smith, Beth A.
Carlson‐Kuhta, Patricia
Horak, Fay B. - Abstract:
- Abstract: Background and Purpose: The backward push and release test (PRT) is a standardized clinical test of postural responses elicited by perturbations. Our goal was to determine reliability of administration and response. This will inform clinical administration and determine whether to develop an instrumented version. Methods: One examiner administered 10 backward PRT trials to adults with Parkinson disease (12), multiple sclerosis (14) and controls (12). We used three‐dimensional motion analysis, force plates and instrumented gloves to measure administration and response. Administration variables were angle of posterior trunk lean and the distance of the centre of mass (CoM) behind the ankle. Postural response variables were latency of postural response from release to step initiation and first compensatory step length. Reliability was measured using the range of variables across trials, comparison of first and later trials, intraclass correlations (ICCs) to measure consistency and correlations between administration and response. Results: There was inherent variability in administration, which affected postural response characteristics. Larger trunk angle and greater CoM–ankle distance were correlated with shorter postural response latencies and larger step lengths. Participant height also had an effect; taller participants had larger trunk angles prior to release resulting in longer latencies and larger step lengths. Using ICCs, consistency of trunk angle was likelyAbstract: Background and Purpose: The backward push and release test (PRT) is a standardized clinical test of postural responses elicited by perturbations. Our goal was to determine reliability of administration and response. This will inform clinical administration and determine whether to develop an instrumented version. Methods: One examiner administered 10 backward PRT trials to adults with Parkinson disease (12), multiple sclerosis (14) and controls (12). We used three‐dimensional motion analysis, force plates and instrumented gloves to measure administration and response. Administration variables were angle of posterior trunk lean and the distance of the centre of mass (CoM) behind the ankle. Postural response variables were latency of postural response from release to step initiation and first compensatory step length. Reliability was measured using the range of variables across trials, comparison of first and later trials, intraclass correlations (ICCs) to measure consistency and correlations between administration and response. Results: There was inherent variability in administration, which affected postural response characteristics. Larger trunk angle and greater CoM–ankle distance were correlated with shorter postural response latencies and larger step lengths. Participant height also had an effect; taller participants had larger trunk angles prior to release resulting in longer latencies and larger step lengths. Using ICCs, consistency of trunk angle was likely acceptable and CoM–ankle distance was high. Consistency of latency was low, while step length was likely acceptable. Discussion: Despite variability in administration and inconsistency in response, different postural response characteristics were detected between patients with different disease states. Based on these results, we will create algorithms to instrument the PRT using inertial movement sensors to collect more sensitive measures of postural responses than observational clinical rating scales. Feedback for appropriate lean angle and calibration for participant height will improve consistency and usefulness of the instrumented PRT. Copyright © 2014 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Physiotherapy research international. Volume 21:Number 1(2016:Mar.)
- Journal:
- Physiotherapy research international
- Issue:
- Volume 21:Number 1(2016:Mar.)
- Issue Display:
- Volume 21, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 21
- Issue:
- 1
- Issue Sort Value:
- 2016-0021-0001-0000
- Page Start:
- 36
- Page End:
- 46
- Publication Date:
- 2014-11-28
- Subjects:
- movement -- nervous system diseases -- postural balance
Physical therapy -- Periodicals
Physical Therapy Modalities -- Periodicals
Physiothérapie -- Périodiques
615.82 - Journal URLs:
- http://eproxy.lib.hku.hk/login?url=http://search.epnet.com/direct.asp?db=aph&jn="GPG"&scope=site ↗
http://www.pri-online.org/ ↗
http://onlinelibrary.wiley.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1471-2865 ↗ - DOI:
- 10.1002/pri.1615 ↗
- Languages:
- English
- ISSNs:
- 1358-2267
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6489.119000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 816.xml