A rapid and sensitive LC‐MS/MS method for the determination of linarin in small‐volume rat plasma and tissue samples and its application to pharmacokinetic and tissue distribution study. (21st September 2015)
- Record Type:
- Journal Article
- Title:
- A rapid and sensitive LC‐MS/MS method for the determination of linarin in small‐volume rat plasma and tissue samples and its application to pharmacokinetic and tissue distribution study. (21st September 2015)
- Main Title:
- A rapid and sensitive LC‐MS/MS method for the determination of linarin in small‐volume rat plasma and tissue samples and its application to pharmacokinetic and tissue distribution study
- Authors:
- Feng, Xinchi
Liu, Youping
Wang, Xin
Di, Xin - Abstract:
- Abstract: A rapid and sensitive LC‐MS/MS method was developed for the determination of linarin in small‐volume rat plasma and tissue sample. Sample preparation was employed by the combination of protein precipitation (PPT) and liquid–liquid extraction (LLE) to allow measurement over a 5‐order‐of‐magnitude concentration range. Fast chromatographic separation was achieved on a Hypersil Gold column (100 × 2.1 mm i.d., 5 µm). Mass spectrometric detection was achieved using a triple‐quadrupole mass spectrometer equipped with an electrospray ionization interface operating in positive ionization mode. Quantification was performed using selected reaction monitoring of precursor‐product ion transitions at m / z 593 → 285 for linarin and m / z 447 → 271 for baicalin (internal standard). The total run time was only 2.8 min per sample. The calibration curves were linear over the concentration range of 0.4–200 µg/mL for PPT and 0.001–1.0 µg/mL for LLE. A lower limit of quantification of 1.0 ng/mL was achieved using only 20 μL of plasma or tissue homogenate. The intra‐ and inter‐day precisions in all samples were ≤14.7%, while the accuracy was within ±5.2% of nominal values. The validated method has been successfully applied to pharmacokinetic and tissue distribution study of linarin. Copyright © 2015 John Wiley & Sons, Ltd.
- Is Part Of:
- Biomedical chromatography. Volume 30:Number 4(2016:Apr.)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 30:Number 4(2016:Apr.)
- Issue Display:
- Volume 30, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 4
- Issue Sort Value:
- 2016-0030-0004-0000
- Page Start:
- 618
- Page End:
- 624
- Publication Date:
- 2015-09-21
- Subjects:
- linarin -- LC–MS/MS -- pharmacokinetics -- tissue distribution -- rats
Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.3605 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1568.xml