A novel label-free fluorescence strategy for methyltransferase activity assay based on dsDNA-templated copper nanoparticles coupled with an endonuclease-assisted signal transduction system. Issue 4 (14th January 2016)
- Record Type:
- Journal Article
- Title:
- A novel label-free fluorescence strategy for methyltransferase activity assay based on dsDNA-templated copper nanoparticles coupled with an endonuclease-assisted signal transduction system. Issue 4 (14th January 2016)
- Main Title:
- A novel label-free fluorescence strategy for methyltransferase activity assay based on dsDNA-templated copper nanoparticles coupled with an endonuclease-assisted signal transduction system
- Authors:
- Lai, Q. Q.
Liu, M. D.
Gu, C. C.
Nie, H. G.
Xu, X. J.
Li, Z. H.
Yang, Z.
Huang, S. M. - Abstract:
- Abstract : A novel label-free fluorescence method by coupling dsDNA-templated CuNPs with endonuclease-assisted signal transduction has been developed for methyltransferase activity assay. Abstract : Evaluating DNA methyltransferase (MTase) activity has received considerable attention due to its significance in the fields of early cancer clinical diagnostics and drug discovery. Herein, we proposed a novel label-free fluorescence method for MTase activity assay by coupling double-stranded DNA (dsDNA)-templated copper nanoparticles (CuNPs) with an endonuclease-assisted signal transduction system. In this strategy, dsDNA molecules were first methylated by DNA adenine methylation (Dam) MTase and then cleaved by the methylation-sensitive restriction endonuclease DpnI. The cleaved DNA fragments could not act as efficient templates for the formation of fluorescent CuNPs and thus no fluorescence signal was produced. Under optimized experimental conditions, the developed strategy exhibited a sensitive fluorescence response to Dam MTase activity. This strategy was also demonstrated to provide an excellent platform to the inhibitor screening for Dam MTase. These results demonstrated the great potential for the practical applications of the proposed strategy for Dam MTase activity assay.
- Is Part Of:
- Analyst. Volume 141:Issue 4(2016)
- Journal:
- Analyst
- Issue:
- Volume 141:Issue 4(2016)
- Issue Display:
- Volume 141, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 141
- Issue:
- 4
- Issue Sort Value:
- 2016-0141-0004-0000
- Page Start:
- 1383
- Page End:
- 1389
- Publication Date:
- 2016-01-14
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c5an02123e ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1414.xml