Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple. (March 2016)
- Record Type:
- Journal Article
- Title:
- Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple. (March 2016)
- Main Title:
- Effect of spectrum measurement position variation on the robustness of NIR spectroscopy models for soluble solids content of apple
- Authors:
- Fan, Shuxiang
Zhang, Baohua
Li, Jiangbo
Huang, Wenqian
Wang, Chaopeng - Abstract:
- Abstract : In this paper, the influence of variation of spectrum measurement position on the near-infrared (NIR) spectroscopy analysis of soluble solids content (SSC) of apple was studied. The spectra were collected around stem, equator and calyx positions for each apple. Partial least squares (PLS) was used to develop compensation models of SSC for each measurement position separately (local position models) and for the full data set containing all positions (global position model). The results indicated that the influence of measurement position on the spectra affected the prediction accuracy of SSC. Compared with the local position models, the global position model was well suited to control the prediction accuracy of the calibration model for SSC with respect to the variation of spectrum measurement position. Next, competitive adaptive reweighted sampling (CARS) was used for the robust global position model to select the most effective wavelengths (EWs). It indicated that the global model established with effective wavelengths (EWs-global position model) achieved more promising results, with rp and RMSEP values for three measurement positions being 0.977, 0.977, 0.955 and 0.409, 0.386, 0.486 °Brix, respectively. Moreover, the local position models based on these effective variables (EWs-local position models) were more accurate than the models built with full range spectrum. The overall results indicated that the EWs-global position model could make the variation ofAbstract : In this paper, the influence of variation of spectrum measurement position on the near-infrared (NIR) spectroscopy analysis of soluble solids content (SSC) of apple was studied. The spectra were collected around stem, equator and calyx positions for each apple. Partial least squares (PLS) was used to develop compensation models of SSC for each measurement position separately (local position models) and for the full data set containing all positions (global position model). The results indicated that the influence of measurement position on the spectra affected the prediction accuracy of SSC. Compared with the local position models, the global position model was well suited to control the prediction accuracy of the calibration model for SSC with respect to the variation of spectrum measurement position. Next, competitive adaptive reweighted sampling (CARS) was used for the robust global position model to select the most effective wavelengths (EWs). It indicated that the global model established with effective wavelengths (EWs-global position model) achieved more promising results, with rp and RMSEP values for three measurement positions being 0.977, 0.977, 0.955 and 0.409, 0.386, 0.486 °Brix, respectively. Moreover, the local position models based on these effective variables (EWs-local position models) were more accurate than the models built with full range spectrum. The overall results indicated that the EWs-global position model could make the variation of spectrum measurement position a negligible interference for SSC prediction. Highlights: Effect of spectrum measurement position on NIR model of apple SSC was studied. The spectrum measurement position affected the prediction accuracy of SSC. The Global model based on effective wavelengths was robust. A potential method for eliminating the effect of the spectrum measurement position. … (more)
- Is Part Of:
- Biosystems engineering. Volume 143(2016:Mar.)
- Journal:
- Biosystems engineering
- Issue:
- Volume 143(2016:Mar.)
- Issue Display:
- Volume 143 (2016)
- Year:
- 2016
- Volume:
- 143
- Issue Sort Value:
- 2016-0143-0000-0000
- Page Start:
- 9
- Page End:
- 19
- Publication Date:
- 2016-03
- Subjects:
- Spectrum measurement position -- Soluble solids content -- NIR -- Apple
Bioengineering -- Periodicals
Agricultural engineering -- Periodicals
Biological systems -- Periodicals
Génie rural -- Périodiques
Systèmes biologiques -- Périodiques
631 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15375110 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biosystemseng.2015.12.012 ↗
- Languages:
- English
- ISSNs:
- 1537-5110
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2089.670500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 266.xml