A comparison of measured room acoustics metrics using a spherical microphone array and conventional methods. (June 2016)
- Record Type:
- Journal Article
- Title:
- A comparison of measured room acoustics metrics using a spherical microphone array and conventional methods. (June 2016)
- Main Title:
- A comparison of measured room acoustics metrics using a spherical microphone array and conventional methods
- Authors:
- Dick, David A.
Vigeant, Michelle C. - Abstract:
- Abstract: The traditional microphone configuration used to measure room impulse responses (IRs) according to ISO 3382:2009 is an omnidirectional and figure-8 microphone pair. IRs measurements were taken in a 2500-seat auditorium to determine how the results from a spherical microphone array (an mh acoustics Eigenmike-em32) compare to those from the traditional microphone setup (a Brüel & Kjær Type-4192 omnidirectional microphone and a Sennheiser MKH30 figure-8 microphone). Measurements were obtained at six receiver locations, with three repetitions each in order to first evaluate repeatability. The metrics considered in this study were: reverberation time (T30), early decay time (EDT), clarity index (C80), strength ( G ), lateral energy fraction ( J LF ) and late lateral energy level ( L J ). Before calculating these quantities, the IRs were filtered to equalize the frequency response of the microphones and sound source. For the spherical array measurements, the omnidirectional (monopole) and figure-8 (dipole) patterns were extracted using beamforming. In terms of repeatability, the average standard deviation of the three measurements at each receiver location averaged across all metrics, receivers, and octave bands was found to be 0.01 just noticeable differences (JNDs). The analysis comparing the measurements from the two microphone configurations yielded differences which were less than 1 JND for the majority of metrics, with a few exceptions of EDT and C80 slightly aboveAbstract: The traditional microphone configuration used to measure room impulse responses (IRs) according to ISO 3382:2009 is an omnidirectional and figure-8 microphone pair. IRs measurements were taken in a 2500-seat auditorium to determine how the results from a spherical microphone array (an mh acoustics Eigenmike-em32) compare to those from the traditional microphone setup (a Brüel & Kjær Type-4192 omnidirectional microphone and a Sennheiser MKH30 figure-8 microphone). Measurements were obtained at six receiver locations, with three repetitions each in order to first evaluate repeatability. The metrics considered in this study were: reverberation time (T30), early decay time (EDT), clarity index (C80), strength ( G ), lateral energy fraction ( J LF ) and late lateral energy level ( L J ). Before calculating these quantities, the IRs were filtered to equalize the frequency response of the microphones and sound source. For the spherical array measurements, the omnidirectional (monopole) and figure-8 (dipole) patterns were extracted using beamforming. In terms of repeatability, the average standard deviation of the three measurements at each receiver location averaged across all metrics, receivers, and octave bands was found to be 0.01 just noticeable differences (JNDs). The analysis comparing the measurements from the two microphone configurations yielded differences which were less than 1 JND for the majority of metrics, with a few exceptions of EDT and C80 slightly above 1 JND. Based on this case study, these results indicate that spherical microphone arrays can be used to obtain valid room IR measurements, which will allow for the development of new metrics utilizing the higher spatial resolution made possible with spherical arrays. … (more)
- Is Part Of:
- Applied acoustics. Volume 107(2016)
- Journal:
- Applied acoustics
- Issue:
- Volume 107(2016)
- Issue Display:
- Volume 107, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 107
- Issue:
- 2016
- Issue Sort Value:
- 2016-0107-2016-0000
- Page Start:
- 34
- Page End:
- 45
- Publication Date:
- 2016-06
- Subjects:
- Spherical microphone array -- Room acoustics -- Spatial measures -- Measurement hardware -- Room impulse response
Acoustical engineering -- Periodicals
Periodicals
620.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0003682X ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/homepage/elecserv.htt ↗ - DOI:
- 10.1016/j.apacoust.2016.01.008 ↗
- Languages:
- English
- ISSNs:
- 0003-682X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1571.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 134.xml