Strategies to reduce wastage of red blood cell units. Issue 2 (28th October 2015)
- Record Type:
- Journal Article
- Title:
- Strategies to reduce wastage of red blood cell units. Issue 2 (28th October 2015)
- Main Title:
- Strategies to reduce wastage of red blood cell units
- Authors:
- Bots, M.
de Grouw, E. P. L. M.
van Rooyen‐Schreurs, I. H. M.
van den Akker, G. J.
Sturk, A.
Klinkspoor, J. H.
Zeerleder, S. S. - Abstract:
- Abstract : Background and objectives: Wastage of red blood cell units (RBCs) due to their inappropriate storage at the clinical ward has become both a financial and ethical challenge in the daily hospital practice. This study was aimed at identifying the extent of RBC wastage and evaluating the effects of various interventions in reducing this wastage. Materials and methods: From January 2011 to March 2011, baseline wastage level was evaluated using temperature‐sensitive labels. Following this initial analysis, various interventions were implemented, including modifying the transfusion practice, intensifying training of and communication with the medical staff and improving the transport conditions. The impact of these interventions on wastage was measured during two periods, and results were compared with baseline wastage level. Results: Based on the extent of label colouring, 7·5% of the units dispensed by the transfusion laboratory were determined as non‐reusable at baseline. After implementation of the various interventions, wastage decreased to 1% of the units dispensed, potentially leading to an annual saving for our hospital of approximately €208·000/$230·600 on the total number of RBCs dispensed. Conclusion: Relative straightforward interventions, such as raising awareness among medical staff and particularly improving transport conditions, had a clear impact on the level of RBC wastage, accommodating the financial issue not to waste public money as well as theAbstract : Background and objectives: Wastage of red blood cell units (RBCs) due to their inappropriate storage at the clinical ward has become both a financial and ethical challenge in the daily hospital practice. This study was aimed at identifying the extent of RBC wastage and evaluating the effects of various interventions in reducing this wastage. Materials and methods: From January 2011 to March 2011, baseline wastage level was evaluated using temperature‐sensitive labels. Following this initial analysis, various interventions were implemented, including modifying the transfusion practice, intensifying training of and communication with the medical staff and improving the transport conditions. The impact of these interventions on wastage was measured during two periods, and results were compared with baseline wastage level. Results: Based on the extent of label colouring, 7·5% of the units dispensed by the transfusion laboratory were determined as non‐reusable at baseline. After implementation of the various interventions, wastage decreased to 1% of the units dispensed, potentially leading to an annual saving for our hospital of approximately €208·000/$230·600 on the total number of RBCs dispensed. Conclusion: Relative straightforward interventions, such as raising awareness among medical staff and particularly improving transport conditions, had a clear impact on the level of RBC wastage, accommodating the financial issue not to waste public money as well as the ethical issue that RBC wastage should be as low as possible. … (more)
- Is Part Of:
- Vox sanguinis. Volume 110:Issue 2(2016)
- Journal:
- Vox sanguinis
- Issue:
- Volume 110:Issue 2(2016)
- Issue Display:
- Volume 110, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 110
- Issue:
- 2
- Issue Sort Value:
- 2016-0110-0002-0000
- Page Start:
- 143
- Page End:
- 149
- Publication Date:
- 2015-10-28
- Subjects:
- blood transfusion -- red blood cell -- temperature‐sensitive labels -- transport boxes -- wastage
Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1423-0410 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vox ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vox.12351 ↗
- Languages:
- English
- ISSNs:
- 0042-9007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9258.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 430.xml