Colon wall motility: comparison of novel quantitative semi‐automatic measurements using cine MRI. Issue 3 (26th November 2015)
- Record Type:
- Journal Article
- Title:
- Colon wall motility: comparison of novel quantitative semi‐automatic measurements using cine MRI. Issue 3 (26th November 2015)
- Main Title:
- Colon wall motility: comparison of novel quantitative semi‐automatic measurements using cine MRI
- Authors:
- Hoad, C. L.
Menys, A.
Garsed, K.
Marciani, L.
Hamy, V.
Murray, K.
Costigan, C.
Atkinson, D.
Major, G.
Spiller, R. C.
Taylor, S. A.
Gowland, P. A. - Abstract:
- Abstract: Background: Recently, cine magnetic resonance imaging (MRI) has shown promise for visualizing movement of the colonic wall, although assessment of data has been subjective and observer dependent. This study aimed to develop an objective and semi‐automatic imaging metric of ascending colonic wall movement, using image registration techniques. Methods: Cine balanced turbo field echo MRI images of ascending colonic motility were acquired over 2 min from 23 healthy volunteers (HVs) at baseline and following two different macrogol stimulus drinks (11 HVs drank 1 L and 12 HVs drank 2 L). Motility metrics derived from large scale geometric and small scale pixel movement parameters following image registration were developed using the post ingestion data and compared to observer grading of wall motion. Inter and intra‐observer variability in the highest correlating metric was assessed using Bland–Altman analysis calculated from two separate observations on a subset of data. Key Results: All the metrics tested showed significant correlation with the observer rating scores. Line analysis (LA) produced the highest correlation coefficient of 0.74 (95% CI: 0.55–0.86), p < 0.001 (Spearman Rho). Bland–Altman analysis of the inter‐ and intra‐observer variability for the LA metric, showed almost zero bias and small limits of agreement between observations (−0.039 to 0.052 intra‐observer and −0.051 to 0.054 inter‐observer, range of measurement 0–0.353). Conclusions & Inferences:Abstract: Background: Recently, cine magnetic resonance imaging (MRI) has shown promise for visualizing movement of the colonic wall, although assessment of data has been subjective and observer dependent. This study aimed to develop an objective and semi‐automatic imaging metric of ascending colonic wall movement, using image registration techniques. Methods: Cine balanced turbo field echo MRI images of ascending colonic motility were acquired over 2 min from 23 healthy volunteers (HVs) at baseline and following two different macrogol stimulus drinks (11 HVs drank 1 L and 12 HVs drank 2 L). Motility metrics derived from large scale geometric and small scale pixel movement parameters following image registration were developed using the post ingestion data and compared to observer grading of wall motion. Inter and intra‐observer variability in the highest correlating metric was assessed using Bland–Altman analysis calculated from two separate observations on a subset of data. Key Results: All the metrics tested showed significant correlation with the observer rating scores. Line analysis (LA) produced the highest correlation coefficient of 0.74 (95% CI: 0.55–0.86), p < 0.001 (Spearman Rho). Bland–Altman analysis of the inter‐ and intra‐observer variability for the LA metric, showed almost zero bias and small limits of agreement between observations (−0.039 to 0.052 intra‐observer and −0.051 to 0.054 inter‐observer, range of measurement 0–0.353). Conclusions & Inferences: The LA index of colonic motility derived from cine MRI registered data provides a quick, accurate and non‐invasive method to detect wall motion within the ascending colon following a colonic stimulus in the form of a macrogol drink. Abstract : This study reports the development of an objective metric of ascending colon motility derived from cine MRI data using image registration techniques to remove respiratory motion and parameterize bowel movements. The line analysis metric produced the highest correlation coefficient with the observer scoring. Inter‐ and intra‐observer variability was low for this metric. … (more)
- Is Part Of:
- Neurogastroenterology & motility. Volume 28:Issue 3(2016)
- Journal:
- Neurogastroenterology & motility
- Issue:
- Volume 28:Issue 3(2016)
- Issue Display:
- Volume 28, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 28
- Issue:
- 3
- Issue Sort Value:
- 2016-0028-0003-0000
- Page Start:
- 327
- Page End:
- 335
- Publication Date:
- 2015-11-26
- Subjects:
- ascending colon -- cine MRI -- imaging metric -- motility
Gastrointestinal system -- Motility -- Periodicals
Gastrointestinal system -- Innervation -- Periodicals
616.33 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=nmo ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2982 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/nmo.12727 ↗
- Languages:
- English
- ISSNs:
- 1350-1925
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.371450
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1022.xml