Pharmacokinetic modeling of multislice dynamic contrast‐enhanced MRI in normal‐healing radial fractures: A pilot study. Issue 3 (2nd September 2015)
- Record Type:
- Journal Article
- Title:
- Pharmacokinetic modeling of multislice dynamic contrast‐enhanced MRI in normal‐healing radial fractures: A pilot study. Issue 3 (2nd September 2015)
- Main Title:
- Pharmacokinetic modeling of multislice dynamic contrast‐enhanced MRI in normal‐healing radial fractures: A pilot study
- Authors:
- Lewis, Mark
Ebreo, Darren
Malcolm, Paul N.
Greenwood, Richard
Patel, Amratlal D.
Kasmai, Bahman
Johnson, Glyn
Toms, Andoni P. - Abstract:
- Abstract : Purpose: To define the range of quantitative pharmacokinetic parameters in normal‐healing bone with dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI). DCE‐MRI is an established technique for characterizing abnormal tissue microvasculature within solid tumors, but has also shown promise for assessing bone and bone marrow. Materials and Methods: In this study ethical approval for eight patients was obtained. Inclusion criteria were an extra‐articular distal radial fracture in patients aged 20–50 years which had united by 6 weeks in plaster cast. This was assessed by an experienced orthopedic surgeon. DCE‐MRI was performed at 1.5T 6 weeks after initial injury. The transfer constant (K trans ), transfer rate (Kep ), and initial area under the curve (IAUC) values for the fracture site and adjacent marrow were obtained for each patient. Results: The mean T 1, K trans, Kep, and IAUC at the fracture site were 1713 (standard deviation [SD] 645), 0.09 (SD 0.07), 0.17 (SD 0.17) and 4.9 (SD 4.4). The relative standard deviation (RSD) for the fracture site ranged from 0.38 to 0.97 and for the adjacent marrow ranged from 0.95–3.88. Within each patient the range of RSDs was 0.04–0.42 for T 1, 0.26–0.91 for K trans, 0.14–1.06 for Kep, and 0.35–0.96 for the IAUC. Conclusion: Pharmacokinetic measures of perfusion can be obtained from healing fractures using DCE‐MRI with "excellent" intraclass correlation coefficients for inter‐ and intrarater reliability. The use ofAbstract : Purpose: To define the range of quantitative pharmacokinetic parameters in normal‐healing bone with dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI). DCE‐MRI is an established technique for characterizing abnormal tissue microvasculature within solid tumors, but has also shown promise for assessing bone and bone marrow. Materials and Methods: In this study ethical approval for eight patients was obtained. Inclusion criteria were an extra‐articular distal radial fracture in patients aged 20–50 years which had united by 6 weeks in plaster cast. This was assessed by an experienced orthopedic surgeon. DCE‐MRI was performed at 1.5T 6 weeks after initial injury. The transfer constant (K trans ), transfer rate (Kep ), and initial area under the curve (IAUC) values for the fracture site and adjacent marrow were obtained for each patient. Results: The mean T 1, K trans, Kep, and IAUC at the fracture site were 1713 (standard deviation [SD] 645), 0.09 (SD 0.07), 0.17 (SD 0.17) and 4.9 (SD 4.4). The relative standard deviation (RSD) for the fracture site ranged from 0.38 to 0.97 and for the adjacent marrow ranged from 0.95–3.88. Within each patient the range of RSDs was 0.04–0.42 for T 1, 0.26–0.91 for K trans, 0.14–1.06 for Kep, and 0.35–0.96 for the IAUC. Conclusion: Pharmacokinetic measures of perfusion can be obtained from healing fractures using DCE‐MRI with "excellent" intraclass correlation coefficients for inter‐ and intrarater reliability. The use of these perfusion parameters is limited by wide patient‐to‐patient variation and slice‐to‐slice variation within patients. J. MAGN. RESON. IMAGING 2016;43:611–619. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 43:Issue 3(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 43:Issue 3(2016)
- Issue Display:
- Volume 43, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 3
- Issue Sort Value:
- 2016-0043-0003-0000
- Page Start:
- 611
- Page End:
- 619
- Publication Date:
- 2015-09-02
- Subjects:
- DCE_MRI -- fracture -- radius -- reliability
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25039 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1151.xml