Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study. (January 2016)
- Record Type:
- Journal Article
- Title:
- Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study. (January 2016)
- Main Title:
- Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients
- Authors:
- Kutyifa, Valentina
Daubert, James P.
Schuger, Claudio
Goldenberg, Ilan
Klein, Helmut
Aktas, Mehmet K.
McNitt, Scott
Stockburger, Martin
Merkely, Bela
Zareba, Wojciech
Moss, Arthur J. - Abstract:
- Abstract : Background—: The Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on the effect of cardiac resynchronization therapy with a cardioverter defibrillator (CRT-D) on the effect of ICD programming. We aimed to elucidate the effect of CRT-D on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D or an ICD, enrolled in MADIT-RIT. Methods and Results—: The primary end point of this study was the first inappropriate ICD therapy. Secondary end points were inappropriate anti-tachycardia pacing and inappropriate ICD shock. The study enrolled 742 (49%) patients with an ICD and 757 (51%) patients with a CRT-D. Patients implanted with a CRT-D had 62% lower risk of inappropriate ICD therapy than those with an ICD only (hazard ratio [HR] =0.38, 95% confidence interval: 0.25–0.57; P <0.001). High-rate cut-off or delayed ventricular tachycardia therapy programming significantly reduced the risk of inappropriate ICD therapy compared with conventional ICD programming in ICD (HR=0.14 [B versus A]; HR=0.21 [C versus A]) and CRT-D patients (HR=0.15 [B versus A]; HR=0.23 [C versus A]; P <0.001 for all). There was a significantAbstract : Background—: The Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on the effect of cardiac resynchronization therapy with a cardioverter defibrillator (CRT-D) on the effect of ICD programming. We aimed to elucidate the effect of CRT-D on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D or an ICD, enrolled in MADIT-RIT. Methods and Results—: The primary end point of this study was the first inappropriate ICD therapy. Secondary end points were inappropriate anti-tachycardia pacing and inappropriate ICD shock. The study enrolled 742 (49%) patients with an ICD and 757 (51%) patients with a CRT-D. Patients implanted with a CRT-D had 62% lower risk of inappropriate ICD therapy than those with an ICD only (hazard ratio [HR] =0.38, 95% confidence interval: 0.25–0.57; P <0.001). High-rate cut-off or delayed ventricular tachycardia therapy programming significantly reduced the risk of inappropriate ICD therapy compared with conventional ICD programming in ICD (HR=0.14 [B versus A]; HR=0.21 [C versus A]) and CRT-D patients (HR=0.15 [B versus A]; HR=0.23 [C versus A]; P <0.001 for all). There was a significant reduction in inappropriate anti-tachycardia pacings in both group and a significant reduction in inappropriate ICD shock in CRT-D patients. Conclusions—: Patients implanted with a CRT-D have lower risk of inappropriate ICD therapy than those with an ICD. Innovative ICD programming significantly reduces the risk of inappropriate ICD therapy in both ICD and CRT-D patients. Clinical Trial Registration—: http://clinicaltrials.gov ; Unique identifier: NCT00947310. … (more)
- Is Part Of:
- Circulation. Volume 9:Number 1(2016)
- Journal:
- Circulation
- Issue:
- Volume 9:Number 1(2016)
- Issue Display:
- Volume 9, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 9
- Issue:
- 1
- Issue Sort Value:
- 2016-0009-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01
- Subjects:
- atrial fibrillation -- cardiac resynchronization therapy -- ICD Programming -- implantable cardioverter–defibrillator -- MADIT-RIT -- supraventricular tachycardia
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.114.001965 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1012.xml