Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial Fibrillation: Results From the Gap-Atrial Fibrillation–German Atrial Fibrillation Competence Network 1 Trial. (January 2016)
- Record Type:
- Journal Article
- Title:
- Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial Fibrillation: Results From the Gap-Atrial Fibrillation–German Atrial Fibrillation Competence Network 1 Trial. (January 2016)
- Main Title:
- Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial Fibrillation
- Authors:
- Kuck, Karl-Heinz
Hoffmann, Boris A.
Ernst, Sabine
Wegscheider, Karl
Treszl, Andras
Metzner, Andreas
Eckardt, Lars
Lewalter, Thorsten
Breithardt, Günter
Willems, Stephan - Abstract:
- Abstract : Background—: Ablation of atrial fibrillation (AF) is an established treatment option for symptomatic patients. It is not known whether complete pulmonary vein isolation (PVI) is superior to incomplete PVI with regard to the patients' clinical outcome. Methods and Results—: Patients with drug-refractory, symptomatic paroxysmal AF were randomly assigned to either incomplete (group A) or complete PVI (group B). In group A, a persistent gap was intentionally left within the circumferential ablation line, whereas in group B, complete PVI without any gaps was intended. At 3 months, all patients underwent invasive reevaluation to assess the rate of persistent PVI. Clinical follow-up was based on daily 30-s transtelephonic ECG transmissions. Primary study end point was the time to first recurrence of (symptomatic or asymptomatic) AF. A total of 233 patients were enrolled (116 in group A and 117 in group B). AF recurrence within 3 months was observed in a total of 161 patients (136 [84.5%] with symptomatic and 25 [15.5%] with asymptomatic AF); AF recurred in 62.2% of group B patients and 79.2% of group A patients ( P <0.001), for a difference in favor of complete PVI of 17.1% (95% confidence interval, 5.3%–28.9%). Invasive restudy in 103 group A patients and 93 group B patients revealed conduction gaps in 92 (89.3%) and 65 (69.9%) patients, respectively. Conclusions—: This study proves the superiority of complete PVI over incomplete PVI with respect to AF recurrence withinAbstract : Background—: Ablation of atrial fibrillation (AF) is an established treatment option for symptomatic patients. It is not known whether complete pulmonary vein isolation (PVI) is superior to incomplete PVI with regard to the patients' clinical outcome. Methods and Results—: Patients with drug-refractory, symptomatic paroxysmal AF were randomly assigned to either incomplete (group A) or complete PVI (group B). In group A, a persistent gap was intentionally left within the circumferential ablation line, whereas in group B, complete PVI without any gaps was intended. At 3 months, all patients underwent invasive reevaluation to assess the rate of persistent PVI. Clinical follow-up was based on daily 30-s transtelephonic ECG transmissions. Primary study end point was the time to first recurrence of (symptomatic or asymptomatic) AF. A total of 233 patients were enrolled (116 in group A and 117 in group B). AF recurrence within 3 months was observed in a total of 161 patients (136 [84.5%] with symptomatic and 25 [15.5%] with asymptomatic AF); AF recurred in 62.2% of group B patients and 79.2% of group A patients ( P <0.001), for a difference in favor of complete PVI of 17.1% (95% confidence interval, 5.3%–28.9%). Invasive restudy in 103 group A patients and 93 group B patients revealed conduction gaps in 92 (89.3%) and 65 (69.9%) patients, respectively. Conclusions—: This study proves the superiority of complete PVI over incomplete PVI with respect to AF recurrence within 3 months. However, the rate of electric reconduction 3 months after PVI is high in patients with initially isolated PVs. Clinical Trial Registration—: URL:http://clinicaltrials.gov ; Unique identifier: NCT00293943. … (more)
- Is Part Of:
- Circulation. Volume 9:Number 1(2016)
- Journal:
- Circulation
- Issue:
- Volume 9:Number 1(2016)
- Issue Display:
- Volume 9, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 9
- Issue:
- 1
- Issue Sort Value:
- 2016-0009-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01
- Subjects:
- arrhythmias, cardiac -- atrial fibrillation -- catheter ablation -- pulmonary veins -- randomized controlled trial
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.115.003337 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1012.xml