Quantitation of the Fe spatial distribution in biological tissue by online double isotope dilution analysis with LA-ICP-MS: a strategy for estimating measurement uncertainty. Issue 1 (10th November 2015)
- Record Type:
- Journal Article
- Title:
- Quantitation of the Fe spatial distribution in biological tissue by online double isotope dilution analysis with LA-ICP-MS: a strategy for estimating measurement uncertainty. Issue 1 (10th November 2015)
- Main Title:
- Quantitation of the Fe spatial distribution in biological tissue by online double isotope dilution analysis with LA-ICP-MS: a strategy for estimating measurement uncertainty
- Authors:
- Douglas, David N.
O'Reilly, Jennifer
O'Connor, Ciaran
Sharp, Barry L.
Goenaga-Infante, Heidi - Abstract:
- Abstract : A strategy, systematically developed, is reported for the quantitative analysis of the Fe spatial distribution in biological tissue using laser ablation with ICP-MS and on-line double isotope dilution analysis. Abstract : A novel strategy is reported for the quantitative analysis of the Fe spatial distribution in biological tissue using laser ablation with ICP-MS and on-line double isotope dilution analysis (LA-ICP-IDMS). The proposed on-line IDMS method involves post-ablation introduction of an isotopically enriched 57 Fe spike solution using a total consumption nebuliser. To investigate the potential applicability of the developed method to biological tissue with varying Fe concentrations (akin to those observed in bio-imaging), the effect of sample-to-calibration standard blend ratio on the accuracy of the Fe data was investigated over a range of 1 : 0.2 to 1 : 10. To achieve this, homogenised sheep brain tissue doped with Fe (251 μg g −1 ) was used as the model sample. Recoveries of 80–109% of the expected Fe concentration in the model tissue sample (as determined by ID-ICP-MS of the tissue digest) were obtained over a sample-to-standard ratio range of 1 : 1 to 1 : 5. A systematic estimation of measurement uncertainty for LA-ICP-IDMS was undertaken and for the first time the mass flow rate of the material was determined via single-IDMS. An overall combined expanded uncertainty ( k = 2) of 15–27% was achieved for ratio matching of 1 : 1 to 1 : 5. The factorsAbstract : A strategy, systematically developed, is reported for the quantitative analysis of the Fe spatial distribution in biological tissue using laser ablation with ICP-MS and on-line double isotope dilution analysis. Abstract : A novel strategy is reported for the quantitative analysis of the Fe spatial distribution in biological tissue using laser ablation with ICP-MS and on-line double isotope dilution analysis (LA-ICP-IDMS). The proposed on-line IDMS method involves post-ablation introduction of an isotopically enriched 57 Fe spike solution using a total consumption nebuliser. To investigate the potential applicability of the developed method to biological tissue with varying Fe concentrations (akin to those observed in bio-imaging), the effect of sample-to-calibration standard blend ratio on the accuracy of the Fe data was investigated over a range of 1 : 0.2 to 1 : 10. To achieve this, homogenised sheep brain tissue doped with Fe (251 μg g −1 ) was used as the model sample. Recoveries of 80–109% of the expected Fe concentration in the model tissue sample (as determined by ID-ICP-MS of the tissue digest) were obtained over a sample-to-standard ratio range of 1 : 1 to 1 : 5. A systematic estimation of measurement uncertainty for LA-ICP-IDMS was undertaken and for the first time the mass flow rate of the material was determined via single-IDMS. An overall combined expanded uncertainty ( k = 2) of 15–27% was achieved for ratio matching of 1 : 1 to 1 : 5. The factors with greatest contribution to the overall uncertainty were the mass of spike, the measured ratio of the standard blend and the mass of calibrant. External calibration with internal standardisation was performed on the same model sample for the purpose of comparison. The measurement uncertainty associated with this calibration approach was for the first time estimated for LA bio-imaging by taking into account the contributions from the signal intensity variance, the errors from least squares regression and concentration of the standards. For external calibration the overall relative expanded uncertainty was approximately 50% ( k = 2), with the uncertainty in the linear least squares regression ( R 2 of 0.9833) and the signal variation being the main contributing factors. The results for Fe in the model sample agreed well with those determined via LA-ICP-IDMS. For the first time, the potential of a LA-ICP-MS isotope dilution calibration strategy to validate higher throughput calibration methodologies ( e.g. matrix-matched external calibration with internal standardisation), as would be required for routine medical applications, has been demonstrated. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 31:Issue 1(2016:Jan.)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 31:Issue 1(2016:Jan.)
- Issue Display:
- Volume 31, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 1
- Issue Sort Value:
- 2016-0031-0001-0000
- Page Start:
- 270
- Page End:
- 279
- Publication Date:
- 2015-11-10
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c5ja00351b ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2451.xml