Review on dynamic and quasi-static buffeting response of transmission lines under synoptic and non-synoptic winds. (1st April 2016)
- Record Type:
- Journal Article
- Title:
- Review on dynamic and quasi-static buffeting response of transmission lines under synoptic and non-synoptic winds. (1st April 2016)
- Main Title:
- Review on dynamic and quasi-static buffeting response of transmission lines under synoptic and non-synoptic winds
- Authors:
- Aboshosha, Haitham
Elawady, Amal
El Ansary, Ayman
El Damatty, Ashraf - Abstract:
- Highlights: This study reviews the literature on the buffeting dynamic and quasi-static response of Transmission Lines. The study focuses on the response under synoptic and non-synoptic (downburst) wind. For the synoptic wind, four design codes are considered for comparison. Limitations and gaps in the current structural design codes are identified. Recommendations to fill out those gaps are provided. Abstract: This study reviews the literature on the dynamic response of a Transmission Line (TL) system under synoptic wind (conventional atmospheric boundary layer) as well as non-synoptic wind loading (downbursts). Gust-induced response for the conductors and the towers are covered and the limitations in the current structural design codes for wind loading are identified. Three main sections are considered in this study covering synoptic wind loading, downburst, and main conclusions and recommendations. For the case of synoptic wind events, four design codes (ASCE 74 2010, AS/NZS 2010, BS 2001, IEC 2003) specialized in TLs are considered for comparison. Using the ASCE 74 as a datum for normalization, a code ratio ( CR ) is evaluated for various parameters to assess the discrepancy between the codes. The code ratio for conductor forces CRFc is found to be ranging between 0.81 and 1.44. For tower forces code ratio CRFt, a discrepancy range of 0.68 and 1.85 is noticed. The study highlights the main reasons behind these discrepancies. For the case of downbursts, the study revealsHighlights: This study reviews the literature on the buffeting dynamic and quasi-static response of Transmission Lines. The study focuses on the response under synoptic and non-synoptic (downburst) wind. For the synoptic wind, four design codes are considered for comparison. Limitations and gaps in the current structural design codes are identified. Recommendations to fill out those gaps are provided. Abstract: This study reviews the literature on the dynamic response of a Transmission Line (TL) system under synoptic wind (conventional atmospheric boundary layer) as well as non-synoptic wind loading (downbursts). Gust-induced response for the conductors and the towers are covered and the limitations in the current structural design codes for wind loading are identified. Three main sections are considered in this study covering synoptic wind loading, downburst, and main conclusions and recommendations. For the case of synoptic wind events, four design codes (ASCE 74 2010, AS/NZS 2010, BS 2001, IEC 2003) specialized in TLs are considered for comparison. Using the ASCE 74 as a datum for normalization, a code ratio ( CR ) is evaluated for various parameters to assess the discrepancy between the codes. The code ratio for conductor forces CRFc is found to be ranging between 0.81 and 1.44. For tower forces code ratio CRFt, a discrepancy range of 0.68 and 1.85 is noticed. The study highlights the main reasons behind these discrepancies. For the case of downbursts, the study reveals that the event's size and its relative location to the tower lead to a number of critical load cases that need to be considered. The study provides important design considerations for both synoptic and non-synoptic winds. At the end of the study, a list of the main gaps existing in current design codes and recommendations to fill out these gaps is provided. … (more)
- Is Part Of:
- Engineering structures. Volume 112(2016:Apr. 01)
- Journal:
- Engineering structures
- Issue:
- Volume 112(2016:Apr. 01)
- Issue Display:
- Volume 112 (2016)
- Year:
- 2016
- Volume:
- 112
- Issue Sort Value:
- 2016-0112-0000-0000
- Page Start:
- 23
- Page End:
- 46
- Publication Date:
- 2016-04-01
- Subjects:
- Dynamic response -- Transmission line -- Conductors -- Synoptic winds -- Non-synoptic downburst -- Gust factor -- Buffeting
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2016.01.003 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2453.xml