Development of human hand phantom containing radiophotoluminescence material. (February 2016)
- Record Type:
- Journal Article
- Title:
- Development of human hand phantom containing radiophotoluminescence material. (February 2016)
- Main Title:
- Development of human hand phantom containing radiophotoluminescence material
- Authors:
- Sato, Fuminobu
Maekawa, Tatsuro
Sakiyama, Tomoki
Zushi, Naoki
Shimizu, Kikuo
Kato, Yushi
Murata, Isao
Yamamoto, Takayoshi
Iida, Toshiyuki - Abstract:
- Abstract: A radiophotoluminescence (RPL) material with high radiation sensitivity was made of polyurethane resin, silver-activated metaphosphate glass particles, and hollow glass microspheres. The density was adjusted to be 1.1 g/cm 3 by controlling the amount of hollow glass microspheres. The response to high-energy photons over 100 keV was similar to that of the tissue-equivalent material (polymethylmethacrylate) because the two electron densities were similar. The RPL response had satisfactory linearity in the dose range from 10 to 6 × 10 4 mGy. An RPL scanner for three-dimensional (3-D) dose measurement was composed of an XYZθ motorized stage, a UV pulse laser, a gated photomultiplier tube (PMT), a red-laser displacement sensor, and an integrating ammeter. The surface profile was measured by the red-laser-displacement sensor. The UV laser was used as an excitation source, and the RPL responses were effectively detected with the gated PMT. An RPL material hand phantom was fabricated to understand the extremity dosimetry of a radiation worker's hand. The hand phantom was exposed to X-rays, and its surface dose profile was obtained by the RPL scanner. Subsequently, the hand phantom was sliced into dozens of square plates using a diamond wire saw. Each inner dose profile was obtained with the RPL scanner. The inner dose profiles were roughly consistent with the computational simulation results. These results indicated that RPL imaging of the hand phantom was useful toAbstract: A radiophotoluminescence (RPL) material with high radiation sensitivity was made of polyurethane resin, silver-activated metaphosphate glass particles, and hollow glass microspheres. The density was adjusted to be 1.1 g/cm 3 by controlling the amount of hollow glass microspheres. The response to high-energy photons over 100 keV was similar to that of the tissue-equivalent material (polymethylmethacrylate) because the two electron densities were similar. The RPL response had satisfactory linearity in the dose range from 10 to 6 × 10 4 mGy. An RPL scanner for three-dimensional (3-D) dose measurement was composed of an XYZθ motorized stage, a UV pulse laser, a gated photomultiplier tube (PMT), a red-laser displacement sensor, and an integrating ammeter. The surface profile was measured by the red-laser-displacement sensor. The UV laser was used as an excitation source, and the RPL responses were effectively detected with the gated PMT. An RPL material hand phantom was fabricated to understand the extremity dosimetry of a radiation worker's hand. The hand phantom was exposed to X-rays, and its surface dose profile was obtained by the RPL scanner. Subsequently, the hand phantom was sliced into dozens of square plates using a diamond wire saw. Each inner dose profile was obtained with the RPL scanner. The inner dose profiles were roughly consistent with the computational simulation results. These results indicated that RPL imaging of the hand phantom was useful to understand extremity dosimetry. Highlights: We developed a highly radiation-sensitive radiophotoluminescence (RPL) material. An RPL material hand phantom was fabricated to understand extremity dosimetry. The 3-D dose distribution in the hand phantom was obtained by RPL imaging. … (more)
- Is Part Of:
- Radiation measurements. Volume 85(2016:Feb.)
- Journal:
- Radiation measurements
- Issue:
- Volume 85(2016:Feb.)
- Issue Display:
- Volume 85 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue Sort Value:
- 2016-0085-0000-0000
- Page Start:
- 18
- Page End:
- 25
- Publication Date:
- 2016-02
- Subjects:
- Radiophotoluminescence (RPL) -- Dosimeter -- 3-D scanner -- Extremity dosimetry -- X-ray irradiation
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2015.12.006 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 449.xml