Comparison of investigator-delineated gross tumor volumes and quality assurance in pancreatic cancer: Analysis of the pretrial benchmark case for the SCALOP trial. Issue 3 (December 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of investigator-delineated gross tumor volumes and quality assurance in pancreatic cancer: Analysis of the pretrial benchmark case for the SCALOP trial. Issue 3 (December 2015)
- Main Title:
- Comparison of investigator-delineated gross tumor volumes and quality assurance in pancreatic cancer: Analysis of the pretrial benchmark case for the SCALOP trial
- Authors:
- Fokas, Emmanouil
Clifford, Charlotte
Spezi, Emiliano
Joseph, George
Branagan, Jennifer
Hurt, Chris
Nixon, Lisette
Abrams, Ross
Staffurth, John
Mukherjee, Somnath - Abstract:
- Abstract: Background and purpose: To evaluate the variation in investigator-delineated volumes and assess plans from the radiotherapy trial quality assurance (RTTQA) program of SCALOP, a phase II trial in locally advanced pancreatic cancer. Materials and methods: Participating investigators ( n = 25) outlined a pre-trial benchmark case as per RT protocol, and the accuracy of investigators' GTV (iGTV) and PTV (iPTV) was evaluated, against the trials team-defined gold standard GTV (gsGTV) and PTV (gsPTV), using both qualitative and geometric analyses. The median Jaccard Conformity Index (JCI) and Geographical Miss Index (GMI) were calculated. Participating RT centers also submitted a radiotherapy plan for this benchmark case, which was centrally reviewed against protocol-defined constraints. Results: Twenty-five investigator-defined contours were evaluated. The median JCI and GMI of iGTVs were 0.57 (IQR: 0.51–0.65) and 0.26 (IQR: 0.15–0.40). For iPTVs, these were 0.75 (IQR: 0.71–0.79) and 0.14 (IQR: 0.11–0.22) respectively. Qualitative analysis showed largest variation at the tumor edges and failure to recognize a peri-pancreatic lymph node. There were no major protocol deviations in RT planning, but three minor PTV coverage deviations were identified. . Conclusions: SCALOP demonstrated considerable variation in iGTV delineation. RTTQA workshops and real-time central review of delineations are needed in future trials.
- Is Part Of:
- Radiotherapy and oncology. Volume 117:Issue 3(2015:Dec.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 117:Issue 3(2015:Dec.)
- Issue Display:
- Volume 117, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 117
- Issue:
- 3
- Issue Sort Value:
- 2015-0117-0003-0000
- Page Start:
- 432
- Page End:
- 437
- Publication Date:
- 2015-12
- Subjects:
- Radiotherapy -- Pancreas -- iGTV -- gsGTV -- Conformity index -- Quality assurance
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2015.08.026 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1845.xml