Measurement of the zygomatic bone and pilot hole technique for safer insertion of zygomaticus implants. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- Measurement of the zygomatic bone and pilot hole technique for safer insertion of zygomaticus implants. Issue 1 (January 2016)
- Main Title:
- Measurement of the zygomatic bone and pilot hole technique for safer insertion of zygomaticus implants
- Authors:
- Takamaru, N.
Nagai, H.
Ohe, G.
Tamatani, T.
Sumida, K.
Kitamura, S.
Miyamoto, Y. - Abstract:
- Abstract: The zygomaticus implant was developed for patients with severe bone resorption of the posterior maxilla. These may eliminate or minimize the need for bone grafting. Although the zygomaticus implant has shown a remarkable success rate in this difficult-to-treat patient population, the method requires an advanced surgical technique and carries an increased risk of complications. There have been few anatomical studies on the zygomatic bone in relation to the insertion of zygomaticus implants. The height and thickness of the zygomatic bone for the insertion were measured in this study. The thickness at the 90° angle point, where the upper margin of the zygomatic arch and the temporal margin of the frontal process of the zygomatic bone intersect and where the apex of the implant penetrates, was found to be 1.8 ± 0.4 mm; this gradually increased inferiorly and anteriorly. Thus, the penetration point of the apex of the zygomaticus implant should be located more inferoanterior to the 90° angle point, as the thickness in this region is thinner than the diameter of the implant. Based on the results of this study, a newer and safer insertion method for the zygomaticus implant using a drill guide is proposed.
- Is Part Of:
- International journal of oral & maxillofacial surgery. Volume 45:Issue 1(2016:Jan.)
- Journal:
- International journal of oral & maxillofacial surgery
- Issue:
- Volume 45:Issue 1(2016:Jan.)
- Issue Display:
- Volume 45, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 45
- Issue:
- 1
- Issue Sort Value:
- 2016-0045-0001-0000
- Page Start:
- 104
- Page End:
- 109
- Publication Date:
- 2016-01
- Subjects:
- maxillary sinus -- sinus floor augmentation -- zygomatic bone -- zygomaticus implant
Mouth -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Dentistry -- Periodicals
Dentistry, Operative
Oral Surgical Procedures
Surgery, Oral
Dentistry
Maxilla -- Surgery
Mouth -- Surgery
Electronic journals
Periodicals
617.52059 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=ijo ↗
http://www.sciencedirect.com/science/journal/09015027 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09015027 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09015027 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijom.2015.07.015 ↗
- Languages:
- English
- ISSNs:
- 0901-5027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.429800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1384.xml