An Experimental Evaluation of Device/Arterial Wall Compliance Mismatch for Four Stent-Graft Devices and a Multi-layer Flow Modulator Device for the Treatment of Abdominal Aortic Aneurysms. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- An Experimental Evaluation of Device/Arterial Wall Compliance Mismatch for Four Stent-Graft Devices and a Multi-layer Flow Modulator Device for the Treatment of Abdominal Aortic Aneurysms. Issue 1 (January 2016)
- Main Title:
- An Experimental Evaluation of Device/Arterial Wall Compliance Mismatch for Four Stent-Graft Devices and a Multi-layer Flow Modulator Device for the Treatment of Abdominal Aortic Aneurysms
- Authors:
- Morris, L.
Stefanov, F.
Hynes, N.
Diethrich, E.B.
Sultan, S. - Abstract:
- Abstract : Objective/background: To investigate experimentally the arterial wall/device compliance mismatch of four stent-graft devices and a multilayer flow modulator within the supra- and infrarenal locations for the treatment of abdominal aortic aneurysms (AAA). Methods: Five devices (MFM, EndurantII, Excluder, Zenith, and Fortron) were tested under physiological flow conditions within a flow simulator system comprising of a patient-specific thin-walled flexible AAA perfusion model with replicated intraluminal thrombus, supported by the spinal column. Devices were submitted to circumferential force tests and implanted in the perfusion model for circumferential arterial pressure/diameter measurements. Parameters, including radial resistive force, supra-/infrarenal compliance, pulsatile arterial energy loss (PAEL), pulse wave velocity (PWV), and wave reflection coefficient (Γ), were computed to characterise the devices' performance. Results: The Zenith and EndurantII devices had the highest radial resistive force (up to 3 N/cm), while the Fortron device had the lowest (0.11 N/cm). Supra- and infrarenal compliance varied between 6.9–5.1 × 10 −4 /mmHg and 4.8–5.4 × 10 −4 /mmHg, respectively. Two devices (EndurantII and Excluder) significantly decreased infrarenal compliance by 13–26% ( p < .001). Four devices increased the PAEL by 13–44% ( p < .006). The PWV ranged from 10.9 m/s (MFM; p = .164) to 15.1 m/s (EndurantII; p < .001). There was an increase of 8–238% ( pAbstract : Objective/background: To investigate experimentally the arterial wall/device compliance mismatch of four stent-graft devices and a multilayer flow modulator within the supra- and infrarenal locations for the treatment of abdominal aortic aneurysms (AAA). Methods: Five devices (MFM, EndurantII, Excluder, Zenith, and Fortron) were tested under physiological flow conditions within a flow simulator system comprising of a patient-specific thin-walled flexible AAA perfusion model with replicated intraluminal thrombus, supported by the spinal column. Devices were submitted to circumferential force tests and implanted in the perfusion model for circumferential arterial pressure/diameter measurements. Parameters, including radial resistive force, supra-/infrarenal compliance, pulsatile arterial energy loss (PAEL), pulse wave velocity (PWV), and wave reflection coefficient (Γ), were computed to characterise the devices' performance. Results: The Zenith and EndurantII devices had the highest radial resistive force (up to 3 N/cm), while the Fortron device had the lowest (0.11 N/cm). Supra- and infrarenal compliance varied between 6.9–5.1 × 10 −4 /mmHg and 4.8–5.4 × 10 −4 /mmHg, respectively. Two devices (EndurantII and Excluder) significantly decreased infrarenal compliance by 13–26% ( p < .001). Four devices increased the PAEL by 13–44% ( p < .006). The PWV ranged from 10.9 m/s (MFM; p = .164) to 15.1 m/s (EndurantII; p < .001). There was an increase of 8–238% ( p < .001) in the reflection coefficient for all devices. Conclusion: Commercially available endovascular devices lower the aortic wall compliance after implantation. The MFM was found to be the most compliant in the suprarenal region, while the Fortron device was the most compliant in the infrarenal region. Choosing the most compliant devices for treating AAAs produces positive gains in the aortic elastic recoil, thus minimising the device related complications. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 51:Issue 1(2016:Jan.)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 51:Issue 1(2016:Jan.)
- Issue Display:
- Volume 51, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 51
- Issue:
- 1
- Issue Sort Value:
- 2016-0051-0001-0000
- Page Start:
- 44
- Page End:
- 55
- Publication Date:
- 2016-01
- Subjects:
- Abdominal aortic aneurysm -- Endovascular aortic repair -- Endograft -- Multilayer flow modulator -- Compliance
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2015.07.041 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2258.xml