Annex and rigid diaphragm effects on the failure analysis and earthquake damages of historic churches. (January 2016)
- Record Type:
- Journal Article
- Title:
- Annex and rigid diaphragm effects on the failure analysis and earthquake damages of historic churches. (January 2016)
- Main Title:
- Annex and rigid diaphragm effects on the failure analysis and earthquake damages of historic churches
- Authors:
- Dal Cin, A.
Russo, S. - Abstract:
- Abstract: Historical churches, in the most of cases, are characterised by the presence of annexes and rigid diaphragm that influence their seismic response. Therefore, this research aims to investigate the disadvantages and the benefits which emerge during the horizontal dynamic actions between these structures. This study presents some analyses carried out on the Gesù Church in Mirandola, which was damaged by the 2012 Northern Italy earthquake. The first fundamental steps have been the geometrical, material and in particular the seismic damage survey. An undamaged finite element model of the actual configuration of the Gesù church with a perfectly connected annex was created and was also considered the same model as an isolated structure. Through these FE models preliminary modal dynamic analyses were conducted in the linear elastic field. Subsequently non-linear static analyses were carried out to investigate the ultimate capacity of the building. The churches are characterised by large halls without internal thorn walls, slender walls, pushing elements and lack of intermediate horizontal connection. All these factors lead each macroelement to have an independent dynamics, showing the absence of box-like behaviour. Since the roof trusses are one of the few structural elements that can determine a better global behaviour, it has been decided to perform the same numerical analyses even in the FE models without the roof, then considering the extreme case of a not effectiveAbstract: Historical churches, in the most of cases, are characterised by the presence of annexes and rigid diaphragm that influence their seismic response. Therefore, this research aims to investigate the disadvantages and the benefits which emerge during the horizontal dynamic actions between these structures. This study presents some analyses carried out on the Gesù Church in Mirandola, which was damaged by the 2012 Northern Italy earthquake. The first fundamental steps have been the geometrical, material and in particular the seismic damage survey. An undamaged finite element model of the actual configuration of the Gesù church with a perfectly connected annex was created and was also considered the same model as an isolated structure. Through these FE models preliminary modal dynamic analyses were conducted in the linear elastic field. Subsequently non-linear static analyses were carried out to investigate the ultimate capacity of the building. The churches are characterised by large halls without internal thorn walls, slender walls, pushing elements and lack of intermediate horizontal connection. All these factors lead each macroelement to have an independent dynamics, showing the absence of box-like behaviour. Since the roof trusses are one of the few structural elements that can determine a better global behaviour, it has been decided to perform the same numerical analyses even in the FE models without the roof, then considering the extreme case of a not effective simply supported roof. Highlights: The analysis of the seismic interaction between church and annex Global greater seismic capacity in the church/annex configurations compared with the isolated structure The rigid diaphragm, as a well structural covering, present a significant increase in seismic capacity. Redistribution of the seismic load among the macroelements, with a significant increase in those of the unconstrained side. … (more)
- Is Part Of:
- Engineering failure analysis. Volume 59(2016:Jan.)
- Journal:
- Engineering failure analysis
- Issue:
- Volume 59(2016:Jan.)
- Issue Display:
- Volume 59 (2016)
- Year:
- 2016
- Volume:
- 59
- Issue Sort Value:
- 2016-0059-0000-0000
- Page Start:
- 122
- Page End:
- 139
- Publication Date:
- 2016-01
- Subjects:
- Historical church -- Annex -- Rigid diaphragm -- Damage identification -- Static non-linear analysis
System failures (Engineering) -- Periodicals
Fracture mechanics -- Periodicals
Reliability (Engineering) -- Periodicals
Pannes -- Périodiques
Rupture, Mécanique de la -- Périodiques
Fiabilité -- Périodiques
Fracture mechanics
Reliability (Engineering)
System failures (Engineering)
Periodicals
Electronic journals
620.112 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13506307 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engfailanal.2015.09.010 ↗
- Languages:
- English
- ISSNs:
- 1350-6307
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3760.991000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1963.xml