Lesion stiffness measured by shear-wave elastography: Preoperative predictor of the histologic underestimation of US-guided core needle breast biopsy. Issue 12 (December 2015)
- Record Type:
- Journal Article
- Title:
- Lesion stiffness measured by shear-wave elastography: Preoperative predictor of the histologic underestimation of US-guided core needle breast biopsy. Issue 12 (December 2015)
- Main Title:
- Lesion stiffness measured by shear-wave elastography: Preoperative predictor of the histologic underestimation of US-guided core needle breast biopsy
- Authors:
- Park, Ah Young
Son, Eun Ju
Kim, Jeong-Ah
Han, Kyunghwa
Youk, Ji Hyun - Abstract:
- Abstract: Objectives: To determine whether lesion stiffness measured by shear-wave elastography (SWE) can be used to predict the histologic underestimation of ultrasound (US)-guided 14-gauge core needle biopsy (CNB) for breast masses. Methods: This retrospective study enrolled 99 breast masses from 93 patients, including 40 high-risk lesions and 59 ductal carcinoma in situ (DCIS), which were diagnosed by US-guided 14-gauge CNB. SWE was performed for all breast masses to measure quantitative elasticity values before US-guided CNB. To identify the preoperative factors associated with histologic underestimation, patients' age, symptoms, lesion size, B-mode US findings, and quantitative SWE parameters were compared according to the histologic upgrade after surgery using the chi-square test, Fisher's exact test, or independent t -test. The independent factors for predicting histologic upgrade were evaluated using multivariate logistic regression analysis. Results: The underestimation rate was 28.3% (28/99) in total, 25.0% (10/40) in high-risk lesions, and 30.5% (18/59) in DCIS. All elasticity values of the upgrade group were significantly higher than those of the non-upgrade group ( P < 0.001). On multivariate analysis, the mean (Odds ratio [OR] = 1.021, P = 0.001), maximum (OR = 1.015, P = 0.008), and minimum (OR = 1.028, P = 0.001) elasticity values were independently associated with histologic underestimation. The patients' age, lesion size, and final assessment categoryAbstract: Objectives: To determine whether lesion stiffness measured by shear-wave elastography (SWE) can be used to predict the histologic underestimation of ultrasound (US)-guided 14-gauge core needle biopsy (CNB) for breast masses. Methods: This retrospective study enrolled 99 breast masses from 93 patients, including 40 high-risk lesions and 59 ductal carcinoma in situ (DCIS), which were diagnosed by US-guided 14-gauge CNB. SWE was performed for all breast masses to measure quantitative elasticity values before US-guided CNB. To identify the preoperative factors associated with histologic underestimation, patients' age, symptoms, lesion size, B-mode US findings, and quantitative SWE parameters were compared according to the histologic upgrade after surgery using the chi-square test, Fisher's exact test, or independent t -test. The independent factors for predicting histologic upgrade were evaluated using multivariate logistic regression analysis. Results: The underestimation rate was 28.3% (28/99) in total, 25.0% (10/40) in high-risk lesions, and 30.5% (18/59) in DCIS. All elasticity values of the upgrade group were significantly higher than those of the non-upgrade group ( P < 0.001). On multivariate analysis, the mean (Odds ratio [OR] = 1.021, P = 0.001), maximum (OR = 1.015, P = 0.008), and minimum (OR = 1.028, P = 0.001) elasticity values were independently associated with histologic underestimation. The patients' age, lesion size, and final assessment category on US of the upgrade group were higher than those of the non-upgrade group ( P = 0.046 for age; P = 0.021 for lesion size; P = 0.030 for US category), but these were not independent predictors of histologic underestimation on multivariate analysis. Conclusion: Breast lesion stiffness quantitatively measured by SWE could be helpful to predict the underestimation of malignancy in US-guided 14-gauge CNB. … (more)
- Is Part Of:
- European journal of radiology. Volume 84:Issue 12(2015)
- Journal:
- European journal of radiology
- Issue:
- Volume 84:Issue 12(2015)
- Issue Display:
- Volume 84, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 84
- Issue:
- 12
- Issue Sort Value:
- 2015-0084-0012-0000
- Page Start:
- 2509
- Page End:
- 2514
- Publication Date:
- 2015-12
- Subjects:
- Shear-wave elastography -- Breast -- Underestimation -- Core needle biopsy
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2015.10.001 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 245.xml