Does a novel penalized likelihood reconstruction of 18F-FDG PET-CT improve signal-to-background in colorectal liver metastases?. Issue 10 (October 2015)
- Record Type:
- Journal Article
- Title:
- Does a novel penalized likelihood reconstruction of 18F-FDG PET-CT improve signal-to-background in colorectal liver metastases?. Issue 10 (October 2015)
- Main Title:
- Does a novel penalized likelihood reconstruction of 18F-FDG PET-CT improve signal-to-background in colorectal liver metastases?
- Authors:
- Parvizi, Nassim
Franklin, James M.
McGowan, Daniel R.
Teoh, Eugene J.
Bradley, Kevin M.
Gleeson, Fergus V. - Abstract:
- Abstract: Purpose: Iterative reconstruction algorithms are widely used to reconstruct positron emission tomography computerised tomography (PET/CT) data. Lesion detection in the liver by 18F-fluorodeoxyglucose PET/CT (18F-FDG-PET/CT) is hindered by 18F-FDG uptake in background liver parenchyma. The aim of this study was to compare semi-quantitative parameters of histologically-proven colorectal liver metastases detected by 18F-FDG-PET/CT using data based on a Bayesian penalised likelihood (BPL) reconstruction, with data based on a conventional time-of-flight (ToF) ordered subsets expectation maximisation (OSEM) reconstruction. Methods: A BPL reconstruction algorithm was used to retrospectively reconstruct sinogram PET data. This data was compared with OSEM reconstructions. A volume of interest was placed within normal background liver parenchyma. Lesions were segmented using automated thresholding. Lesion maximum standardised uptake value (SUVmax ), standard deviation of background liver parenchyma SUV, signal-to-background ratio (SBR), and signal-to-noise ratio (SNR) were collated. Data was analysed using paired Student's t -tests and the Pearson correlation. Results: Forty-two liver metastases from twenty-four patients were included in the analysis. The average lesion SUVmax increased from 8.8 to 11.6 ( p < 0.001) after application of the BPL algorithm, with no significant difference in background noise. SBR increased from 4.0 to 4.9 ( p < 0.001) and SNR increased fromAbstract: Purpose: Iterative reconstruction algorithms are widely used to reconstruct positron emission tomography computerised tomography (PET/CT) data. Lesion detection in the liver by 18F-fluorodeoxyglucose PET/CT (18F-FDG-PET/CT) is hindered by 18F-FDG uptake in background liver parenchyma. The aim of this study was to compare semi-quantitative parameters of histologically-proven colorectal liver metastases detected by 18F-FDG-PET/CT using data based on a Bayesian penalised likelihood (BPL) reconstruction, with data based on a conventional time-of-flight (ToF) ordered subsets expectation maximisation (OSEM) reconstruction. Methods: A BPL reconstruction algorithm was used to retrospectively reconstruct sinogram PET data. This data was compared with OSEM reconstructions. A volume of interest was placed within normal background liver parenchyma. Lesions were segmented using automated thresholding. Lesion maximum standardised uptake value (SUVmax ), standard deviation of background liver parenchyma SUV, signal-to-background ratio (SBR), and signal-to-noise ratio (SNR) were collated. Data was analysed using paired Student's t -tests and the Pearson correlation. Results: Forty-two liver metastases from twenty-four patients were included in the analysis. The average lesion SUVmax increased from 8.8 to 11.6 ( p < 0.001) after application of the BPL algorithm, with no significant difference in background noise. SBR increased from 4.0 to 4.9 ( p < 0.001) and SNR increased from 10.6 to 13.1 ( p < 0.001) using BPL. There was a statistically significant negative correlation between lesion size and the percentage increase in lesion SUVmax ( p = 0.03). Conclusions: This BPL reconstruction algorithm improved SNR and SBR for colorectal liver metastases detected by 18F-FDG-PET/CT, increasing the lesion SUVmax without increasing background liver SUV or image noise. This may improve the detection of FDG-avid focal liver lesions and the diagnostic performance of clinical 18F-FDG-PET/CT in this setting, with the largest impact for small foci. … (more)
- Is Part Of:
- European journal of radiology. Volume 84:Issue 10(2015)
- Journal:
- European journal of radiology
- Issue:
- Volume 84:Issue 10(2015)
- Issue Display:
- Volume 84, Issue 10 (2015)
- Year:
- 2015
- Volume:
- 84
- Issue:
- 10
- Issue Sort Value:
- 2015-0084-0010-0000
- Page Start:
- 1873
- Page End:
- 1878
- Publication Date:
- 2015-10
- Subjects:
- Positron emission tomography -- Colorectal liver metastases -- Signal-to-noise -- Signal-to-background -- Reconstruction
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2015.06.025 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 37.xml