Epicardial Catheter Ablation Using High-Intensity Ultrasound: Validation in a Swine Model. (December 2015)
- Record Type:
- Journal Article
- Title:
- Epicardial Catheter Ablation Using High-Intensity Ultrasound: Validation in a Swine Model. (December 2015)
- Main Title:
- Epicardial Catheter Ablation Using High-Intensity Ultrasound
- Authors:
- Nazer, Babak
Salgaonkar, Vasant
Diederich, Chris J.
Jones, Peter D.
Duggirala, Srikant
Tanaka, Yasuaki
Ng, Bennett
Sievers, Richard
Gerstenfeld, Edward P. - Abstract:
- Abstract : Background—: Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, while sparing superficial structures. We developed and tested an epicardial HIU ablation catheter in a closed chest, in vivo swine model. Methods and Results—: The HIU catheter is an internally cooled, 14-French, side-facing catheter, integrated with A-mode ultrasound guidance. Swine underwent percutaneous subxyphoid epicardial access and ablation with HIU (n=10 swine) at 15, 20, and 30 W. Compared with irrigated radiofrequency lesions in control swine (n = 5), HIU demonstrated increased lesion depth (HIU 11.6±3.2 mm versus radiofrequency 4.7±1.6 mm; mean±SD) and epicardial sparing (HIU 2.9±2.1 mm versus radiofrequency 0.1±0.2 mm) at all HIU powers, and increased lesion volume at HIU 20 and 30 W ( P <0.0001 for all comparisons). HIU ablation over coronary arteries and surrounding epicardial fat resulted in deep lesions with normal angiographic flow. Histological disruption of coronary adventitia, but not media or intima, was noted in 44% of lesions. Conclusions—: Compared with radiofrequency, HIU ablation in vivo demonstrates significantly deeper and larger lesions withAbstract : Background—: Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, while sparing superficial structures. We developed and tested an epicardial HIU ablation catheter in a closed chest, in vivo swine model. Methods and Results—: The HIU catheter is an internally cooled, 14-French, side-facing catheter, integrated with A-mode ultrasound guidance. Swine underwent percutaneous subxyphoid epicardial access and ablation with HIU (n=10 swine) at 15, 20, and 30 W. Compared with irrigated radiofrequency lesions in control swine (n = 5), HIU demonstrated increased lesion depth (HIU 11.6±3.2 mm versus radiofrequency 4.7±1.6 mm; mean±SD) and epicardial sparing (HIU 2.9±2.1 mm versus radiofrequency 0.1±0.2 mm) at all HIU powers, and increased lesion volume at HIU 20 and 30 W ( P <0.0001 for all comparisons). HIU ablation over coronary arteries and surrounding epicardial fat resulted in deep lesions with normal angiographic flow. Histological disruption of coronary adventitia, but not media or intima, was noted in 44% of lesions. Conclusions—: Compared with radiofrequency, HIU ablation in vivo demonstrates significantly deeper and larger lesions with greater epicardial sparing in a dose-dependent manner. Further development of this catheter may lead to a promising alternative to epicardial radiofrequency ablation. … (more)
- Is Part Of:
- Circulation. Volume 8:Number 6(2015)
- Journal:
- Circulation
- Issue:
- Volume 8:Number 6(2015)
- Issue Display:
- Volume 8, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 8
- Issue:
- 6
- Issue Sort Value:
- 2015-0008-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12
- Subjects:
- catheter ablation -- epicardium -- phrenic nerve -- swine -- ventricular tachycardia
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.115.003547 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2617.xml