Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial. Issue 10013 (2nd January 2016)
- Record Type:
- Journal Article
- Title:
- Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial. Issue 10013 (2nd January 2016)
- Main Title:
- Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial
- Authors:
- Haude, Michael
Ince, Hüseyin
Abizaid, Alexandre
Toelg, Ralph
Lemos, Pedro Alves
von Birgelen, Clemens
Christiansen, Evald Høj
Wijns, William
Neumann, Franz-Josef
Kaiser, Christoph
Eeckhout, Eric
Lim, Soo Teik
Escaned, Javier
Garcia-Garcia, Hector M
Waksman, Ron - Abstract:
- Summary: Background: Absorbable scaffolds were designed to overcome the limitations of conventional, non-absorbable metal-based drug-eluting stents. So far, only polymeric absorbable scaffolds are commercially available. We aimed to assess the safety and performance of a novel second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) in patients with de-novo coronary artery lesions. Methods: We did this prospective, multicentre, non-randomised, first-in-man trial at 13 percutaneous coronary intervention centres in Belgium, Brazil, Denmark, Germany, Singapore, Spain, Switzerland, and the Netherlands. Eligible patients had stable or unstable angina or documented silent ischaemia, and a maximum of two de-novo lesions with a reference vessel diameter between 2·2 mm and 3·7 mm. Clinical follow-up was scheduled at months 1, 6, 12, 24, and 36. Patients were scheduled for angiographic follow-up at 6 months, and a subgroup of patients was scheduled for intravascular ultrasound, optical coherence tomography, and vasomotion assessment. All patients were recommended to take dual antiplatelet treatment for at least 6 months. The primary endpoint was in-segment late lumen loss at 6 months. We did analysis by intention to treat. This trial is registered withClinicalTrials.gov, numberNCT01960504 . Findings: Between Oct 8, 2013, and May 22, 2015, we enrolled 123 patients with 123 coronary target lesions. At 6 months, mean in-segment late lumen loss was 0·27 mm (SD 0·37), andSummary: Background: Absorbable scaffolds were designed to overcome the limitations of conventional, non-absorbable metal-based drug-eluting stents. So far, only polymeric absorbable scaffolds are commercially available. We aimed to assess the safety and performance of a novel second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) in patients with de-novo coronary artery lesions. Methods: We did this prospective, multicentre, non-randomised, first-in-man trial at 13 percutaneous coronary intervention centres in Belgium, Brazil, Denmark, Germany, Singapore, Spain, Switzerland, and the Netherlands. Eligible patients had stable or unstable angina or documented silent ischaemia, and a maximum of two de-novo lesions with a reference vessel diameter between 2·2 mm and 3·7 mm. Clinical follow-up was scheduled at months 1, 6, 12, 24, and 36. Patients were scheduled for angiographic follow-up at 6 months, and a subgroup of patients was scheduled for intravascular ultrasound, optical coherence tomography, and vasomotion assessment. All patients were recommended to take dual antiplatelet treatment for at least 6 months. The primary endpoint was in-segment late lumen loss at 6 months. We did analysis by intention to treat. This trial is registered withClinicalTrials.gov, numberNCT01960504 . Findings: Between Oct 8, 2013, and May 22, 2015, we enrolled 123 patients with 123 coronary target lesions. At 6 months, mean in-segment late lumen loss was 0·27 mm (SD 0·37), and angiographically discernable vasomotion was documented in 20 (80%) of 25 patients. Intravascular ultrasound assessments showed a preservation of the scaffold area (mean 6·24 mm 2 [SD 1·15] post-procedure vs 6·21 mm 2 [1·22] at 6 months) with a low mean neointimal area (0·08 mm 2 [0·09]), and optical coherence tomography did not detect any intraluminal mass. Target lesion failure occurred in four (3%) patients: one (<1%) patient died from cardiac death, one (<1%) patient had periprocedural myocardial infarction, and two (2%) patients needed clinically driven target lesion revascularisation. No definite or probable scaffold thrombosis was observed. Interpretation: Our findings show that implantation of the DREAMS 2G device in de-novo coronary lesions is feasible, with favourable safety and performance outcomes at 6 months. This novel absorbable metal scaffold could be an alternative to absorbable polymeric scaffolds for treatment of obstructive coronary disease. Funding: Biotronik AG. … (more)
- Is Part Of:
- Lancet. Volume 387:Issue 10013(2016)
- Journal:
- Lancet
- Issue:
- Volume 387:Issue 10013(2016)
- Issue Display:
- Volume 387, Issue 10013 (2016)
- Year:
- 2016
- Volume:
- 387
- Issue:
- 10013
- Issue Sort Value:
- 2016-0387-10013-0000
- Page Start:
- 31
- Page End:
- 39
- Publication Date:
- 2016-01-02
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Medicine
Electronic journals
Periodicals
610.5 - Journal URLs:
- http://www.thelancet.com/ ↗
http://www.sciencedirect.com/science/journal/01406736 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/S0140-6736(15)00447-X ↗
- Languages:
- English
- ISSNs:
- 0140-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5146.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1424.xml