Sixty-Four–Section Cardiac Computed Tomography in Mechanical Prosthetic Heart Valve Dysfunction: Thrombus or Pannus. (December 2015)
- Record Type:
- Journal Article
- Title:
- Sixty-Four–Section Cardiac Computed Tomography in Mechanical Prosthetic Heart Valve Dysfunction: Thrombus or Pannus. (December 2015)
- Main Title:
- Sixty-Four–Section Cardiac Computed Tomography in Mechanical Prosthetic Heart Valve Dysfunction
- Authors:
- Gündüz, Sabahattin
Özkan, Mehmet
Kalçik, Macit
Gürsoy, Ozan Mustafa
Astarcioğlu, Mehmet Ali
Karakoyun, Süleyman
Aykan, Ahmet Çağri
Biteker, Murat
Gökdeniz, Tayyar
Kaya, Hasan
Yesin, Mahmut
Duran, Nilüfer Ekşi
Sevinç, Deniz
Güneysu, Tahsin - Abstract:
- Abstract : Background—: Distinguishing pannus and thrombus in patients with prosthetic valve dysfunction is essential for the selection of proper treatment. We have investigated the utility of 64-slice multidetector computed tomography (MDCT) in distinguishing between pannus and thrombus, the latter amenable to thrombolysis. Methods and Results—: Sixty-two (23 men, mean age 44±14 years) patients with suspected mechanical prosthetic valve dysfunction assessed by transesophageal echocardiography were included in this prospective observational trial. Subsequently, MDCT was performed before any treatment was started. Periprosthetic masses were detected by MDCT in 46 patients, and their attenuation values were measured as Hounsfield Units (HU). Patients underwent thrombolysis unless contraindicated, and those with a contraindication or failed thrombolysis underwent surgery. A mass which was completely lysed or surgically detected as a clot was classified as thrombus, whereas a mass which was surgically detected as tissue overgrowth was classified as pannus. A definitive diagnosis could be achieved in 37 patients with 39 MDCT masses (22 thrombus and 17 pannus). The mean attenuation value of 22 thrombotic masses was significantly lower than that in 17 pannus (87±59 versus 322±122; P <0.001). Area under the receiver operating characteristic curve was 0.96 (95% confidence interval: 0.91–0.99; P <0.001), and a cutoff point of HU≥145 provided high sensitivity (87.5%) and specificityAbstract : Background—: Distinguishing pannus and thrombus in patients with prosthetic valve dysfunction is essential for the selection of proper treatment. We have investigated the utility of 64-slice multidetector computed tomography (MDCT) in distinguishing between pannus and thrombus, the latter amenable to thrombolysis. Methods and Results—: Sixty-two (23 men, mean age 44±14 years) patients with suspected mechanical prosthetic valve dysfunction assessed by transesophageal echocardiography were included in this prospective observational trial. Subsequently, MDCT was performed before any treatment was started. Periprosthetic masses were detected by MDCT in 46 patients, and their attenuation values were measured as Hounsfield Units (HU). Patients underwent thrombolysis unless contraindicated, and those with a contraindication or failed thrombolysis underwent surgery. A mass which was completely lysed or surgically detected as a clot was classified as thrombus, whereas a mass which was surgically detected as tissue overgrowth was classified as pannus. A definitive diagnosis could be achieved in 37 patients with 39 MDCT masses (22 thrombus and 17 pannus). The mean attenuation value of 22 thrombotic masses was significantly lower than that in 17 pannus (87±59 versus 322±122; P <0.001). Area under the receiver operating characteristic curve was 0.96 (95% confidence interval: 0.91–0.99; P <0.001), and a cutoff point of HU≥145 provided high sensitivity (87.5%) and specificity (95.5%) in discriminating pannus from thrombus. Complete lysis was more common for masses with HU<90 compared with those with HU 90 to 145 (100% versus 42.1%; P =0.007). Conclusions—: Sixty-four slice MDCT is helpful in identifying masses amenable to thrombolysis in patients with prosthetic valve dysfunction. A high (HU≥145) attenuation suggests pannus overgrowth, whereas a lower value is associated with thrombus formation. A higher attenuation (HU>90) is associated with reduced lysis rates. … (more)
- Is Part Of:
- Circulation. Volume 8:Number 12(2015)
- Journal:
- Circulation
- Issue:
- Volume 8:Number 12(2015)
- Issue Display:
- Volume 8, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 8
- Issue:
- 12
- Issue Sort Value:
- 2015-0008-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12
- Subjects:
- multidetector computed tomography -- prosthetic heart valves -- sensitivity and specificity -- thrombosis -- transesophageal echocardiography
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.115.003246 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 348.xml