Amplitude-integrated EEG for detection of neonatal seizures: a systematic review. (December 2015)
- Record Type:
- Journal Article
- Title:
- Amplitude-integrated EEG for detection of neonatal seizures: a systematic review. (December 2015)
- Main Title:
- Amplitude-integrated EEG for detection of neonatal seizures: a systematic review
- Authors:
- Rakshasbhuvankar, Abhijeet
Paul, Saritha
Nagarajan, Lakshmi
Ghosh, Soumya
Rao, Shripada - Abstract:
- Highlights: aEEG has relatively low sensitivity and specificity for the diagnosis of neonatal seizures. aEEG cannot be recommended as the mainstay for diagnosis and management of neonatal seizures. There is an urgent need of well-designed studies to address the issue definitively. Abstract: Purpose: Amplitude-integrated electroencephalogram (aEEG) is being used increasingly for monitoring seizures in neonatal units. Its accuracy, compared with "the gold-standard" conventional elecroencephalogram (cEEG) is still not well established. We aimed to conduct a systematic review to evaluate the diagnostic accuracy of aEEG when compared with cEEG, for detection of neonatal seizures. Method: A systematic review was conducted using the Cochrane methodology. EMBASE, CINAHL and PubMed databases were searched in September 2014. Studies comparing simultaneous recordings of cEEG and aEEG for detection of seizures in neonatal population were included. QUADAS 2 tool was used to examine "risk of bias" and "applicability". Results: Ten studies (patient sample 433) were included. Risk of bias was high in five studies, unclear in one and low in four. For the detection of individual seizures, when "aEEG with raw trace" was used, median sensitivity was 76% (range: 71–85), and specificity 85% (range: 39–96). When "aEEG without raw trace" was used, median sensitivity was 39% (range: 25–80) and specificity 95% (range: 50–100). Detailed meta-analysis could not be done because of significantHighlights: aEEG has relatively low sensitivity and specificity for the diagnosis of neonatal seizures. aEEG cannot be recommended as the mainstay for diagnosis and management of neonatal seizures. There is an urgent need of well-designed studies to address the issue definitively. Abstract: Purpose: Amplitude-integrated electroencephalogram (aEEG) is being used increasingly for monitoring seizures in neonatal units. Its accuracy, compared with "the gold-standard" conventional elecroencephalogram (cEEG) is still not well established. We aimed to conduct a systematic review to evaluate the diagnostic accuracy of aEEG when compared with cEEG, for detection of neonatal seizures. Method: A systematic review was conducted using the Cochrane methodology. EMBASE, CINAHL and PubMed databases were searched in September 2014. Studies comparing simultaneous recordings of cEEG and aEEG for detection of seizures in neonatal population were included. QUADAS 2 tool was used to examine "risk of bias" and "applicability". Results: Ten studies (patient sample 433) were included. Risk of bias was high in five studies, unclear in one and low in four. For the detection of individual seizures, when "aEEG with raw trace" was used, median sensitivity was 76% (range: 71–85), and specificity 85% (range: 39–96). When "aEEG without raw trace" was used, median sensitivity was 39% (range: 25–80) and specificity 95% (range: 50–100). Detailed meta-analysis could not be done because of significant clinical/methodological heterogeneity. Seizure detection was better when interpreted by experienced clinicians. Seizures with low amplitude/brief duration and those occurring away from aEEG leads were less likely to be detected. Conclusion: Studies included in the systematic review showed aEEG to have relatively low and variable sensitivity and specificity. Based on the available evidence, aEEG cannot be recommended as the mainstay for diagnosis and management of neonatal seizures. There is an urgent need of well-designed studies to address this issue definitively. … (more)
- Is Part Of:
- Seizure. Volume 33(2015)
- Journal:
- Seizure
- Issue:
- Volume 33(2015)
- Issue Display:
- Volume 33, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 33
- Issue:
- 2015
- Issue Sort Value:
- 2015-0033-2015-0000
- Page Start:
- 90
- Page End:
- 98
- Publication Date:
- 2015-12
- Subjects:
- Electroencephalography -- Cerebral function monitor -- aEEG -- Diagnostic accuracy study -- Neonatal seizure
aEEG amplitude-integrated electroencephalogram -- cEEG conventional electroencephalogram -- EEG electroencephalogram -- HIE hypoxic ischaemic encephalopathy -- NPV negative predictive value -- PPV positive predictive value -- PWS patients with seizures -- QUADAS Quality Assessment of Diagnostic Accuracy Studies
Epilepsy -- Periodicals
Epilepsy -- Periodicals
Seizures -- Periodicals
Épilepsie -- Périodiques
Electronic journals
Electronic journals
616.853 - Journal URLs:
- http://www.seizure-journal.com/ ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13550306 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10591311 ↗
http://www.sciencedirect.com/science/journal/10591311 ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journals/seiz/ ↗ - DOI:
- 10.1016/j.seizure.2015.09.014 ↗
- Languages:
- English
- ISSNs:
- 1059-1311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8229.100000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 668.xml