Ting, Lim Sin - Abstract:
- Abstract: The incidence of diabetes and diabetic retinopathy has been shown to be increasing worldwide. While ophthalmologists struggle to treat this retinopathy, they are also faced with an increment of diabetic referrals for eye screening. Screening and early detection of diabetic retinopathy are crucial to help reduce the incidence of visual morbidity and visual loss. In most countries, diabetic retinopathy assessments are done manually. This is time consuming and is a cause of additional clinical workloads. Clinicians are now aware of the need for an automated system for grading Diabetic Retinopathy (DR) that can help in tracing abnormalities in patients' retinas based on their fundus images, and assist in grading the retina conditions accordingly. This will lead to more effective assessment methods, as well as providing a second opinion to the ophthalmologist during diagnosis. This paper presents an overview of various methods of automated DR grading assessment systems that can complement manual assessments. Tortuosity of the blood vessels is introduced as one of the significant features that can be quantified and associated with DR stages for the grading assessment. From this review, it can be concluded that the automated system has a huge potential for wider acceptance in real life applications. However, there is still some space for improvement for a more robust system. Nevertheless, the DR automated grading assessment system is foreseen as being widely embraced byAbstract: The incidence of diabetes and diabetic retinopathy has been shown to be increasing worldwide. While ophthalmologists struggle to treat this retinopathy, they are also faced with an increment of diabetic referrals for eye screening. Screening and early detection of diabetic retinopathy are crucial to help reduce the incidence of visual morbidity and visual loss. In most countries, diabetic retinopathy assessments are done manually. This is time consuming and is a cause of additional clinical workloads. Clinicians are now aware of the need for an automated system for grading Diabetic Retinopathy (DR) that can help in tracing abnormalities in patients' retinas based on their fundus images, and assist in grading the retina conditions accordingly. This will lead to more effective assessment methods, as well as providing a second opinion to the ophthalmologist during diagnosis. This paper presents an overview of various methods of automated DR grading assessment systems that can complement manual assessments. Tortuosity of the blood vessels is introduced as one of the significant features that can be quantified and associated with DR stages for the grading assessment. From this review, it can be concluded that the automated system has a huge potential for wider acceptance in real life applications. However, there is still some space for improvement for a more robust system. Nevertheless, the DR automated grading assessment system is foreseen as being widely embraced by researchers and ophthalmologists in the future. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 24:(2015)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 24:(2015)
- Issue Display:
- Volume 24, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 24
- Issue:
- 2015
- Issue Sort Value:
- 2015-0024-2015-0000
- Page Start:
- 72
- Page End:
- 82
- Publication Date:
- 2016-02
- Subjects:
- Diabetic retinopathy (DR) -- Digital fundus image -- Tortuosity -- Automated DR grading
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2015.09.011 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1670.xml